ANCHOR-SUNDYN: A novel endstation for time resolved spectroscopy at the ALOISA beamline
In this report we illustrate the instrumental developments involving the branchline of the
ALOISA beamline at the Elettra synchrotron, with the setup of the ANCHOR-SUNDYN …
ALOISA beamline at the Elettra synchrotron, with the setup of the ANCHOR-SUNDYN …
Bunch-resolved diagnostics for a future electron-storage ring
G Schiwietz, JG Hwang, A Jankowiak… - Nuclear Instruments and …, 2021 - Elsevier
The upgrade of the BESSY II light source in Berlin towards a variable pulse-length storage-
ring will lead to a complex bunch-filling pattern. This may involve co-existing electron …
ring will lead to a complex bunch-filling pattern. This may involve co-existing electron …
Excitation density in time-resolved water window soft X-ray spectroscopies: Experimental constraints in the detection of excited states
Time-resolved X-ray spectroscopies have the potential of unveiling ultrafast processes with
chemical sensitivity, but their widespread application is still withheld by technical and …
chemical sensitivity, but their widespread application is still withheld by technical and …
[HTML][HTML] Pump–probe x-ray microscopy of photo-induced magnetization dynamics at MHz repetition rates
We present time-resolved scanning x-ray microscopy measurements with picosecond photo-
excitation via a tailored infrared pump laser at a scanning transmission x-ray microscope …
excitation via a tailored infrared pump laser at a scanning transmission x-ray microscope …
[PDF][PDF] Status of a double slit interferometer for transverse beam size measurements at BESSY II
The upgrade of the BESSY II storage ring to BESSY VSR [1] demands additional beam
diagnostics for machine commissioning and development. Especially bunch resolved …
diagnostics for machine commissioning and development. Especially bunch resolved …
[PDF][PDF] Status and prospects of the BESSY II injector system
T Atkinson, W Anders, H Glass, P Goslawski… - 7th Int. Particle …, 2016 - inspirehep.net
The BESSY II injector system consists of a 50 MeV Linac, installed in preparation for TopUp
operation, and a fastramping Booster synchrotron. The system provides injection efficiencies …
operation, and a fastramping Booster synchrotron. The system provides injection efficiencies …
Development of the electron-beam diagnostics for the future BESSY-VSR storage ring
G Schiwietz, JG Hwang, M Koopmans… - Journal of Physics …, 2018 - iopscience.iop.org
This contribution focusses on the different types of new or improved electron-beam monitors
at BESSY II for bunch resolved measurements under future BESSY-VSR conditions. A new …
at BESSY II for bunch resolved measurements under future BESSY-VSR conditions. A new …
[PDF][PDF] Study on HOM power levels in the BESSY VSR module
A Tsakanian, HW Glock, A Velez… - 8th Int. Particle …, 2017 - accelconf.web.cern.ch
The BESSY VSR project represents a novel approach of SRF cavity application in the
storage rings. To provide a high overvoltage for bunch compression L-band SRF cavities are …
storage rings. To provide a high overvoltage for bunch compression L-band SRF cavities are …
[PDF][PDF] An optical diagnostic beamline for the BESSY II booster
As part of the global refurbishment of the injector at BESSY II, a new optical beamline has
been installed in the booster. This paper covers the conceptual design: incorporating the …
been installed in the booster. This paper covers the conceptual design: incorporating the …
[PDF][PDF] VSR injector upgrade at BESSY II
BESSY VSR is a fully funded project at the Helmholtz-Zentrum in Berlin (HZB). The objective
is to produce simultaneously both long and short pulses in the storage ring. The implications …