Soil organic matter characterization by fourier transform ion cyclotron resonance mass spectrometry (FTICR MS): A critical review of sample preparation, analysis, and …
The biogeochemical cycling of soil organic matter (SOM) plays a central role in regulating
soil health, water quality, carbon storage, and greenhouse gas emissions. Thus, many …
soil health, water quality, carbon storage, and greenhouse gas emissions. Thus, many …
[HTML][HTML] An assessment of quality assurance/quality control efforts in high resolution mass spectrometry non-target workflows for analysis of environmental samples
B Schulze, Y Jeon, S Kaserzon, AL Heffernan… - TrAC Trends in …, 2020 - Elsevier
The application of non-target analysis (NTA), a comprehensive approach to characterize
unknown chemicals, including chemicals of emerging concern has seen a steady increase …
unknown chemicals, including chemicals of emerging concern has seen a steady increase …
[HTML][HTML] Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
KK Murray, RK Boyd, MN Eberlin… - Pure and Applied …, 2013 - degruyter.com
This document contains recommendations for terminology in mass spectrometry.
Development of standard terms dates back to 1974 when the IUPAC Commission on …
Development of standard terms dates back to 1974 when the IUPAC Commission on …
Formularity: software for automated formula assignment of natural and other organic matter from ultrahigh-resolution mass spectra
Ultrahigh resolution mass spectrometry, such as Fourier transform ion cyclotron resonance
mass spectrometry (FT ICR MS), can resolve thousands of molecular ions in complex …
mass spectrometry (FT ICR MS), can resolve thousands of molecular ions in complex …
Petroleomics: Chemistry of the underworld
AG Marshall, RP Rodgers - Proceedings of the National …, 2008 - National Acad Sciences
Each different molecular elemental composition—eg, CcHhNnOoSs—has a different exact
mass. With sufficiently high mass resolving power (m/Δ m 50%≈ 400,000, in which m is …
mass. With sufficiently high mass resolving power (m/Δ m 50%≈ 400,000, in which m is …
Fundamentals of molecular formula assignment to ultrahigh resolution mass data of natural organic matter
Ultrahigh-resolution mass spectrometry via the Fourier transform ion cyclotron resonance
technique (FT-ICR-MS) allows the identification of thousands of different molecular formulas …
technique (FT-ICR-MS) allows the identification of thousands of different molecular formulas …
Natural organic matter and the event horizon of mass spectrometry
N Hertkorn, M Frommberger, M Witt, BP Koch… - Analytical …, 2008 - ACS Publications
Soils, sediments, freshwaters, and marine waters contain natural organic matter (NOM), an
exceedingly complex mixture of organic compounds that collectively exhibit a nearly …
exceedingly complex mixture of organic compounds that collectively exhibit a nearly …
High resolution mass spectrometry
F Xian, CL Hendrickson, AG Marshall - Analytical chemistry, 2012 - ACS Publications
This review focuses on recent advances in instrumentation, techniques, and applications of
the highest resolution mass analyzers (multipass time of flight (TOF), orbitrap, and Fourier …
the highest resolution mass analyzers (multipass time of flight (TOF), orbitrap, and Fourier …
Developments in FT‐ICR MS instrumentation, ionization techniques, and data interpretation methods for petroleomics
Because of the increasing importance of heavy and unconventional crude oil as an energy
source, there is a growing need for petroleomics: the pursuit of more complete and detailed …
source, there is a growing need for petroleomics: the pursuit of more complete and detailed …
Advanced instrumental approaches for characterization of marine dissolved organic matter: extraction techniques, mass spectrometry, and nuclear magnetic …
K Mopper, A Stubbins, JD Ritchie, HM Bialk… - Chemical …, 2007 - ACS Publications
Dissolved organic matter (DOM) is operationally defined as the fraction that will pass
through a filter of a nominal pore size (usually between 0.1 and 1.0 μm). DOM accounts for …
through a filter of a nominal pore size (usually between 0.1 and 1.0 μm). DOM accounts for …