[HTML][HTML] Paravalvular leak after transcatheter aortic valve implantation its incidence, diagnosis, clinical implications, prevention, management, and future perspectives …

S Bhushan, X Huang, Y Li, S He, L Mao, W Hong… - Current Problems in …, 2022 - Elsevier
Paravalvular leak (PVL) is very common after TAVI and has been reported to have a
negative impact on both short-and long-term survival. The current study identified incidence …

Current therapeutic options in aortic stenosis

MT Boskovski, TG Gleason - Circulation research, 2021 - Am Heart Assoc
Aortic stenosis is the most common valvular disease requiring valve replacement. Valve
replacement therapies have undergone progressive evolution since the 1960s. Over the last …

Transcatheter valve-in-valve aortic valve replacement as an alternative to surgical re-replacement

P Deharo, A Bisson, J Herbert, T Lacour… - Journal of the American …, 2020 - jacc.org
Background Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) and redo
surgical aortic valve replacement (SAVR) represent the 2 treatments for aortic bioprosthesis …

Mechanical versus bioprosthetic valve for aortic valve replacement: systematic review and meta-analysis of reconstructed individual participant data

PT Tasoudis, DN Varvoglis, E Vitkos… - European Journal of …, 2022 - academic.oup.com
OBJECTIVES The aim of this study was to compare biological versus mechanical aortic
valve replacement. METHODS We searched MEDLINE, Scopus and Cochrane Library …

Valve-in-valve transcatheter implantation versus redo surgical aortic valve replacement

AH Malik, S Yandrapalli, S Zaid, SS Shetty… - The American Journal of …, 2020 - Elsevier
Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) for a failing prosthesis is
an appealing alternative to redo surgical AVR. We utilized data from the US National …

Prosthesis-patient mismatch following aortic and mitral valves replacement–A comprehensive review

A Joury, A Duran, M Stewart, YE Gilliland… - Progress in …, 2022 - Elsevier
Prothesis-patient mismatch (PPM) occurs when there is a mismatch between the effective
orifice area (EOA) of the prosthetic valve and the required cardiac output to meet the need of …

Valve‐in‐valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement: a systematic review and meta‐analysis

A Ahmed, KH Levy - Journal of Cardiac Surgery, 2021 - Wiley Online Library
Abstract Background/Aim With the growing contemporary use of bioprosthetic valves, whose
limited long‐term durability has been well‐documented, an increase in the need for …

Transcatheter aortic valve replacement: Past, present, and future

A Srinivasan, F Wong, B Wang - Clinical Cardiology, 2024 - Wiley Online Library
Transcatheter aortic valve replacement (TAVR) has emerged as a ground‐breaking,
minimally invasive alternative to traditional open‐heart surgery, primarily designed for …

Isolated redo aortic valve replacement versus valve-in-valve transcatheter valve replacement

PM Patel, E Chiou, Y Cao, J Binongo… - The Annals of Thoracic …, 2021 - Elsevier
Background Clinical outcomes of redo surgical aortic valve replacement (redo-SAVR)
compared with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) are poorly …

Treatment of failed aortic bioprostheses: an evaluation of conventional redo surgery and transfemoral transcatheter aortic valve-in-valve implantation

FJ Woitek, G Stachel, P Kiefer, S Haussig… - International Journal of …, 2020 - Elsevier
Background The use of bioprostheses for surgical aortic valve replacement increased
substantially within the last years. In case of prosthesis failure, re-SAVR is standard of care …