Self‐gated 4D multiphase, steady‐state imaging with contrast enhancement (MUSIC) using rotating cartesian K‐space (ROCK): validation in children with congenital …

F Han, Z Zhou, E Han, Y Gao… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To develop and validate a cardiac‐respiratory self‐gating strategy for the recently
proposed multiphase steady‐state imaging with contrast enhancement (MUSIC) technique …

High efficiency coronary MR angiography with nonrigid cardiac motion correction

J Pang, Y Chen, Z Fan, C Nguyen… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose To improve the coronary visualization quality of four‐dimensional (4D) coronary
MR angiography (MRA) through cardiac motion correction and iterative reconstruction …

Segmented golden ratio radial reordering with variable temporal resolution for dynamic cardiac MRI

F Han, Z Zhou, S Rapacchi, KL Nguyen… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose Golden ratio (GR) radial reordering allows for retrospective choice of temporal
resolution by providing a near‐uniform k‐space sampling within any reconstruction window …

Golden angle dual‐inversion recovery acquisition coupled with a flexible time‐resolved sparse reconstruction facilitates sequence timing in high‐resolution coronary …

G Ginami, J Yerly, PG Masci… - Magnetic resonance in …, 2017 - Wiley Online Library
Purpose The need for performing dual‐inversion recovery (DIR) coronary vessel wall MRI in
correspondence to minimal cardiac motion and optimal blood signal nulling is a major …

A fast, noniterative approach for accelerated high‐temporal resolution cine‐CMR using dynamically interleaved streak removal in the power‐spectral encoded domain …

K Kawaji, MB Patel, CG Cantrell, A Tanaka… - Medical …, 2017 - Wiley Online Library
Purpose To introduce a pair of accelerated non‐Cartesian acquisition principles that when
combined, exploit the periodicity of k‐space acquisition, and thereby enable acquisition of …

Phase contrast coronary blood velocity mapping with both high temporal and spatial resolution using triggered Golden Angle rotated Spiral k‐t Sparse Parallel …

D Zhu, G Bonanno, AG Hays… - Magnetic resonance …, 2021 - Wiley Online Library
Purpose High temporal and spatial resolutions are required for coronary blood flow
measures. Current spiral breath‐hold phase contrast (PC) MRI at 3T focus on either high …

Free-breathing non-contrast MR angiography

RT Seethamraju, RR Gill - US Patent 10,670,684, 2020 - Google Patents
A system includes acquisition of a predetermined number of three-dimensional sub-frames
from patient tissue using a T1-weighted radial sampling sequence and without contrast …

Quantification of Imaging Markers at Different MRI Contrast Weightings, Vasculature, and Across Field Strengths

VS Nguyen - 2024 - search.proquest.com
Quantitative MRI measures physical characteristics of tissue, which creates a set scale with
units that allows longitudinal monitoring and cross-patient and cross-center studies. It …

Fast motion robust abdominal stack of stars imaging using coil compression and soft gating

T Zhang, TA Cashen, K Wang, A Fischer… - proceedings of the …, 2017 - archive.ismrm.org
Stack of stars trajectory with golden angle ordering provides better motion robustness than
Cartesian imaging for abdominal MRI. However, image reconstruction for non-Cartesian …

Phase-cycled steady-state free precession imaging

X Bi, Y Natsuaki, K Johnson, G Laub - US Patent 10,145,926, 2018 - Google Patents
A system includes applying, to patient tissue, a first imaging sequence comprising first
balanced gradient pulse trains and RF pulses, where phases of successive RF pulses in the …