Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors

M Yuqing, C Jianrong, W Xiaohua - TRENDS in Biotechnology, 2004 - cell.com
The response performance of amperometric biosensors can be likened to that of an
uncovered electrode because the non-conducting polymer films used to develop these …

[图书][B] Mathematical modeling of biosensors

R Baronas, F Ivanauskas, J Kulys - 2021 - Springer
This is the second edition of the monography “Mathematical Modeling of Biosensors”
prepared by R. Baronas, F. Ivanauskas and J. Kulys and published by Springer in 2010. In …

Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor

A Kausaite-Minkstimiene, V Mazeiko… - Biosensors and …, 2010 - Elsevier
In this article a new method for fabrication of enzymatic electrodes suitable for design of
amperometric glucose biosensor and/or anode of biofuel cell powered by glucose is …

Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline

H Zhou, H Chen, S Luo, J Chen, W Wei… - Biosensors and …, 2005 - Elsevier
A sensitive and selective amperometric glucose biosensor based on platinum microparticles
dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) …

A high-performance glucose biosensor using covalently immobilised glucose oxidase on a poly (2, 6-diaminopyridine)/carbon nanotube electrode

MA Kamyabi, N Hajari, APF Turner, A Tiwari - Talanta, 2013 - Elsevier
A highly-sensitive glucose biosensor amenable to ultra-miniaturisation was fabricated by
immobilisation of glucose oxidase (GOx), onto a poly (2, 6-diaminopyridine)/multi-walled …

Nonlinear effects of diffusion limitations on the response and sensitivity of amperometric biosensors

R Baronas - Electrochimica Acta, 2017 - Elsevier
The dependencies of the internal and external diffusion limitations on the response and
sensitivity of amperometric biosensors are investigated computationally using a two …

An electrochemical sensing method for the determination of levodopa using a poly (4-methyl-ortho-phenylenediamine)/MWNT modified GC electrode

MA Kamyabi, N Rahmanian - Analytical Methods, 2015 - pubs.rsc.org
A glassy carbon electrode (GCE) modified with poly 4-methyl-ortho-phenylenediamine (4-
MoPD) and multi-wall carbon nanotubes (MWNTs) was used for selective and sensitive …

[HTML][HTML] Electrocatalytic oxidation of dopamine, ascorbic acid and uric acid at poly2, 6diaminopyridine on the surface of carbon nanotubes/gc electrodes

MA Kamyabi, MA Shafiee - Journal of the Brazilian Chemical Society, 2012 - SciELO Brasil
The preparation and application of poly-(2, 6-diaminopyridine) on the surface of a glassy
carbon electrode (GCE) modified with multi-walled carbon nanotubes (CNTs) are reported …

[PDF][PDF] Protective membranes at electrochemical biosensors

A Ambrózy, L Hlavatá, J Labuda - Acta Chimica Slovaca, 2013 - sciendo.com
The primary role of the biosensor is to specifically detect an analyte using biochemical
reaction or interaction mediated by isolated biomolecules, organelles, whole cells or …

Glucose Oxidase Captured into Electropolymerized p-Coumaric Acid towards the Development of a Glucose Biosensor

G Valdés-Ramírez, L Galicia - Chemosensors, 2023 - mdpi.com
An electrochemical biosensor based on the immobilization of glucose oxidase into an
electropolymerized p-coumaric acid membrane on a Pt electrode has been developed and …