An extensive collection of evaluation indicators to assess occupants' health and comfort in indoor environment

F Fantozzi, M Rocca - Atmosphere, 2020 - mdpi.com
Today, the effects of the indoor environment on occupants' health and comfort represent a
very important topic and requires a holistic approach in which the four main environmental …

Experimental and numerical analysis of the autoignition behavior of NH3 and NH3/H2 mixtures at high pressure

L Dai, S Gersen, P Glarborg, H Levinsky… - Combustion and flame, 2020 - Elsevier
Measurements of autoignition delay times of NH 3 and NH 3/H 2 mixtures in a rapid
compression machine are reported at pressures from 20–75 bar and temperatures in the …

[HTML][HTML] Performance evaluation of active chilled beam systems for office buildings–A literature review

H Latif, G Hultmark, S Rahnama, A Maccarini… - Sustainable Energy …, 2022 - Elsevier
Abstract The applications of Active Chilled Beam (ACB) technology have increased over the
two decades and received a lot of attention in research publications due to its ability to …

Effect of sensor position on the performance of CO2-based demand controlled ventilation

G Pei, D Rim, S Schiavon, M Vannucci - Energy and Buildings, 2019 - Elsevier
CO 2-based demand controlled ventilation (DCV) can save energy while maintaining
acceptable indoor air quality. CO 2 concentration may vary within an occupied space and it …

Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads

HJ Chen, B Moshfegh, M Cehlin - Building and Environment, 2013 - Elsevier
This paper presents the flow and temperature field within an office using impinging jet
ventilation (IJV) under different heat loads ranging from 17 to 65 W per square meter floor …

Indoor airflow and contaminant transport in a room with coupled displacement ventilation and passive-chilled-beam systems

Z Shi, Z Lu, Q Chen - Building and Environment, 2019 - Elsevier
Displacement ventilation (DV) is now widely used in enclosed environments such as office
buildings. Although DV can provide good indoor air quality, its ability to remove heat is …

An experimental investigation into stratum ventilation for the cooling of an office with asymmetrically distributed heat gains

C Huan, FH Wang, Z Lin, XZ Wu, ZJ Ma, ZH Wang… - Building and …, 2016 - Elsevier
The performance of stratum ventilation in an office with a glazed façade was investigated. An
electric heating film, hung on a side wall of the test chamber, was employed to simulate the …

Thermal environment in simulated offices with convective and radiant cooling systems under cooling (summer) mode of operation

P Mustakallio, Z Bolashikov, K Kostov, A Melikov… - Building and …, 2016 - Elsevier
The thermal environment in a double office room and in a six-person meeting room obtained
with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling …

Thermal and ventilation performance of combined passive chilled beam and displacement ventilation systems

W Shan, D Rim - Energy and Buildings, 2018 - Elsevier
Chilled beams provide sensible cooling to an occupied space by using chilled water flowing
through modular beams mounted to a room ceiling. Previous studies show that active chilled …

Thermal uniformity in an open plan room with an active chilled beam system and conventional air distribution systems

KN Rhee, MS Shin, SH Choi - Energy and Buildings, 2015 - Elsevier
An active chilled beam (ACB) system is known to be not only energy-efficient, but also
advantageous to high indoor environment quality. For this reason, its application for indoor …