Saturated‐core fault current limiters for AC power systems: towards reliable, economical and better performance application
With the continuous expansion of power grid capacity, the problem of short‐circuit current
exceeding the standard is becoming increasingly serious. Fault current limiter is a promising …
exceeding the standard is becoming increasingly serious. Fault current limiter is a promising …
Conceptual design and evaluation of a resistive-type SFCL for efficient fault ride through in a DFIG
ZC Zou, XY Chen, CS Li, XY Xiao… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
To satisfy the fault ride through (FRT) requirements from both the grid side and the in-grid
doubly fed induction generator (DFIG) itself simultaneously, we propose a novel FRT …
doubly fed induction generator (DFIG) itself simultaneously, we propose a novel FRT …
Architecture, voltage and components for a turboelectric distributed propulsion electric grid
MJ Armstrong, M Blackwelder, A Bollman, C Ross… - 2015 - pureportal.strath.ac.uk
The development of a wholly superconducting turboelectric distributed propulsion system
presents hide unique opportunities for the aerospace industry. However, this transition from …
presents hide unique opportunities for the aerospace industry. However, this transition from …
Design and performance test of a 20-kV DC superconducting fault current limiter
J Sun, J Du, Y Li, S Mo, Y Cai… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
A resistive-type dc superconducting fault current limiter (SFCL) is developed for the fault
current limiting at the Suzhou Nami substation. The rated voltage and current are 20 kV and …
current limiting at the Suzhou Nami substation. The rated voltage and current are 20 kV and …
[HTML][HTML] Superconducting fault current limiter (SFCL) for fail-safe DC-DC conversion: from power electronic device to micro grid protection
In DC micro grids and networks, DC-DC power converters having a large number of
semiconductor-based power electronic devices are usually adopted to interconnect the …
semiconductor-based power electronic devices are usually adopted to interconnect the …
Development of superconducting power devices in Europe
P Tixador - Physica C: Superconductivity and its applications, 2010 - Elsevier
Europe celebrated last year (2008) the 100-year anniversary of the first liquefaction of
helium by H. Kammerling Onnes in Leiden. It led to the discovery of superconductivity in …
helium by H. Kammerling Onnes in Leiden. It led to the discovery of superconductivity in …
Design and test of current limiting modules using YBCO-coated conductors
W Schmidt, B Gamble, HP Kraemer… - Superconductor …, 2009 - iopscience.iop.org
Within the cooperation between American Superconductor Corporation (AMSC) and
Siemens Corporate Technology we have investigated the fault current limiting performance …
Siemens Corporate Technology we have investigated the fault current limiting performance …
A novel five-leg design for performance improvement of three-phase presaturated core fault-current limiter
M Eladawy, IA Metwally - IEEE Transactions on Magnetics, 2018 - ieeexplore.ieee.org
In this paper, a novel five-leg design of non-superconducting, three-phase, presaturated
core fault-current limiter (PCFCL) is proposed based on the time-domain, electromagnetic …
core fault-current limiter (PCFCL) is proposed based on the time-domain, electromagnetic …
Design and tests of prototype hybrid superconducting fault current limiter with fast switch
JB Na, YJ Kim, JY Jang, KS Ryu… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
This paper deals with design and operating tests of prototype hybrid superconducting fault
current limiter (SFCL) which is series connected non-inductive solenoid resistive coil and …
current limiter (SFCL) which is series connected non-inductive solenoid resistive coil and …
Live-grid installation and field testing of the first Italian superconducting fault current limiter
L Martini, M Bocchi, M Ascade… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
Since 2009, Ricerca sul Sistema Energetico SpA has been involved in the development of a
resistive-type superconducting fault current limiter (SFCL) for MV applications to be installed …
resistive-type superconducting fault current limiter (SFCL) for MV applications to be installed …