State-of-the-art review: Seismic design and performance assessment of special concentrically braced frames developed for complex industrial building structures
AD Wasse, K Dai, J Wang, R Sharbati - International Journal of Steel …, 2024 - Springer
This state-of-the-art review comprehensively evaluates the seismic design and performance
assessment of concentrically braced frame (CBF) systems, specifically focusing on special …
assessment of concentrically braced frame (CBF) systems, specifically focusing on special …
[PDF][PDF] A review on BRB and SC-BRB members in building structures
SMB Haider, D Lee - Struct. Eng. Mech, 2021 - researchgate.net
Buckling restrained bracing (BRB) was firstly introduced in Japan construction industry in
year 1989. With time, BRB performance has been advanced to self-centering BRB (SC-BRB) …
year 1989. With time, BRB performance has been advanced to self-centering BRB (SC-BRB) …
Optimization and analysis of hysteretic energy dissipators in reinforced concrete frame structures of five, 10 and 15 stories
D Dominguez-Santos - International Journal of Protective …, 2024 - journals.sagepub.com
Frame structures are especially affected by earthquakes, due to their low lateral resistance.
The use of energy dissipators may be a suitable solution for these structures; however, the …
The use of energy dissipators may be a suitable solution for these structures; however, the …
A review of retrofitting in the structural steel buildings using bracing systems
ZQ Hassan, S Al-Wazni - IOP Conference Series: Earth and …, 2023 - iopscience.iop.org
The multi-storey buildings and towers that are constructed of steel frames are exposed to
lateral loads such as wind loads, earthquakes and explosions, which cause a vibrational …
lateral loads such as wind loads, earthquakes and explosions, which cause a vibrational …
Eccentricity effect on the cyclic response of braced frame type-V
Eccentricity on the braced frames can sometimes not be avoided to facilitate some structural
considerations, such as openings. V-type braced frames are among the most widely used …
considerations, such as openings. V-type braced frames are among the most widely used …
Seismic response of SMRFs retrofitted with bracing systems and nonlinear fluid viscous dampers under near and far field ground motion
A Ziraoui, B Kissi, H Aaya, O Outassafte - Journal of Building Pathology …, 2025 - Springer
The steel structures resistance capacity to seismic loads depends on the material's behavior,
the structural member sizes, how its members are connected to each other's, and the steel …
the structural member sizes, how its members are connected to each other's, and the steel …
[PDF][PDF] To Study and Analyze Effects of Bracing in Design of Building
S Sawarkar, S Satone - International Journal for Research in Applied …, 2022 - academia.edu
High rise structure thanks to its exposure to varied gravity loads, lateral loads and therefore
the exponential height of structure has become a costlier solution. The increasing cost of …
the exponential height of structure has become a costlier solution. The increasing cost of …
Studi Komparasi Perilaku Gedung Beton Bertulang dengan Ketidakberaturan Vertikal Tipe 2 Menggunakan Dinding Geser dan Rangka Bresing Konsentrik Inverted-V
DJ Tatang, LF Tjong - … Teknik Sipil: Majalah Ilmiah Teknik Sipil, 2022 - journals.ums.ac.id
Dinding geser umumnya digunakan pada struktur rangka beton bertulang, sedangkan
bresing baja paling sering digunakan pada struktur baja. Pemberian bresing baja internal …
bresing baja paling sering digunakan pada struktur baja. Pemberian bresing baja internal …
[图书][B] Efficiency of Carbon Fiber Composite Structural Systems for Tall Buildings: A Parametric Simulation Based Framework for Finite Element Analysis
PR Khairnar - 2022 - search.proquest.com
The rate of global urban migration has increased drastically over the last century. With
increasing population, the need for dense urban habitats is growing. Tall buildings are at the …
increasing population, the need for dense urban habitats is growing. Tall buildings are at the …
Ductility of Y-type eccentric braced frame (EBF) under cyclic loading
An Eccentric Braced Frame (EBF) has often been chosen in situations that disable the
structure to use Concentric Braced Frame (CBF), such as opening installation. In planning …
structure to use Concentric Braced Frame (CBF), such as opening installation. In planning …