LVRT enhancement of a grid-tied PMSG-based wind farm using static VAR compensator
This paper presents an efficient Low Voltage Ride Through (LVRT) control scheme for a
10.0 MW grid-tied Permanent Magnet Synchronous Generator (PMSG)-based wind farm …
10.0 MW grid-tied Permanent Magnet Synchronous Generator (PMSG)-based wind farm …
Optimized Wind Turbine Emulator based on an AC to DC Motor Generator Set
Y Aljarhizi, A Nouaiti, E Al Ibrahmi, C Boutahiri… - … , Technology & Applied …, 2023 - etasr.com
This study presents an Optimized Wind Turbine Emulator (OWTE) based on a DC generator
driven by a three-phase Induction Motor (IM). The IM speed is varied using an AC drive that …
driven by a three-phase Induction Motor (IM). The IM speed is varied using an AC drive that …
Improved Interleaved Boost Converter with Soft-Switching: Analysis and Experimental Validation
M Popuri, VVSK Bhajana, MK Maharana… - … , Technology & Applied …, 2023 - etasr.com
This paper proposes a novel interleaved boost converter for renewable energy applications.
The two-phase interleaved boost converter was improved with lossless passive snubber …
The two-phase interleaved boost converter was improved with lossless passive snubber …