Pediatric and Congenital Cardiovascular Disease Research Challenges and Opportunities: JACC Review Topic of the Week
AR Opotowsky, KY Allen, EM Bucholz, KM Burns… - Journal of the American …, 2022 - jacc.org
Abstract The National Heart, Lung, and Blood Institute convened a workshop in August 2021
to identify opportunities in pediatric and congenital cardiovascular research that would …
to identify opportunities in pediatric and congenital cardiovascular research that would …
Computational modeling of the Penn State Fontan circulation assist device
To address the increasing number of failing Fontan patients, Penn State University and the
Penn State Hershey Medical Center are developing a centrifugal blood pump for long-term …
Penn State Hershey Medical Center are developing a centrifugal blood pump for long-term …
Feasibility of an animal model for cavopulmonary support with a double-outflow pump
M Granegger, A Escher, B Karner, M Kainz… - ASAIO …, 2023 - journals.lww.com
Both single-and double-outflow cavopulmonary assist devices (CPADs) were recently
proposed for the Fontan population, whereas single-outflow configurations were evaluated …
proposed for the Fontan population, whereas single-outflow configurations were evaluated …
Experimental hemodynamics within the Penn state Fontan circulatory assist device
SV Ponnaluri, EJ Christensen… - Journal of …, 2022 - asmedigitalcollection.asme.org
For children born with a single functional ventricle, the Fontan operation bypasses the right
ventricle by forming a four-way total cavopulmonary connection and adapts the existing …
ventricle by forming a four-way total cavopulmonary connection and adapts the existing …
Anatomical Compliance of Cavopulmonary Assist Device Designs: A Virtual Fitting Study in Fontan Patients
B Karner, A Escher, T Schorn, K Narayanaswamy… - ASAIO …, 2023 - journals.lww.com
Several device designs for cavopulmonary mechanical circulatory support (MCS) are under
investigation, however, challenged by the Fontan population's heterogeneity in size …
investigation, however, challenged by the Fontan population's heterogeneity in size …
Dielectric elastomer actuator-based valveless pump as Fontan failure assist device: introduction and preliminary study
OBJECTIVES Fontan failure refers to a condition in which the Fontan circulation, a surgical
procedure used to treat certain congenital heart defects, becomes insufficient, leading to …
procedure used to treat certain congenital heart defects, becomes insufficient, leading to …
[HTML][HTML] The horizon of pediatric cardiac critical care
U Pollak, Y Feinstein, CN Mannarino… - Frontiers in …, 2022 - frontiersin.org
Pediatric Cardiac Critical Care (PCCC) is a challenging discipline where decisions require a
high degree of preparation and clinical expertise. In the modern era, outcomes of neonates …
high degree of preparation and clinical expertise. In the modern era, outcomes of neonates …
Fontan Assist Devices, a Systematic Review of Twenty Years of Experimental and In Vivo Trials
A AbdelMassih, Z Allami, M AlTatari, R AbuGhosh… - 2024 - preprints.org
Background: Fontan completion is the last stage of univentricular repair, which drains the
inferior vena cava against gravity to a higher-pressure pulmonary arterial circulation. The …
inferior vena cava against gravity to a higher-pressure pulmonary arterial circulation. The …