Measurement of angle kappa and centration in refractive surgery
CY Park, SY Oh, RS Chuck - Current opinion in ophthalmology, 2012 - journals.lww.com
There is a growing body of evidence that emphasizes the consideration of angle kappa in
refractive surgery. Ignoring angle kappa may sometimes result in decentered treatment and …
refractive surgery. Ignoring angle kappa may sometimes result in decentered treatment and …
Angle Kappa and its importance in refractive surgery
M Moshirfar, RN Hoggan… - Oman journal of …, 2013 - journals.lww.com
Angle kappa is the difference between the pupillary and visual axis. This measurement is of
paramount consideration in refractive surgery, as proper centration is required for optimal …
paramount consideration in refractive surgery, as proper centration is required for optimal …
Negative dysphotopsia: causes and rationale for prevention and treatment
JT Holladay, MJ Simpson - Journal of Cataract & Refractive Surgery, 2017 - Elsevier
Purpose To determine the cause of negative dysphotopsia using standard ray-tracing
techniques and identify the primary and secondary causative factors. Setting Department of …
techniques and identify the primary and secondary causative factors. Setting Department of …
Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation
Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL
implantation | Eye Skip to main content Thank you for visiting nature.com. You are using a …
implantation | Eye Skip to main content Thank you for visiting nature.com. You are using a …
Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses
Y Fu, J Kou, D Chen, D Wang, Y Zhao, M Hu… - Journal of Cataract & …, 2019 - Elsevier
Purpose To assess the influence of angle kappa (κ) and angle alpha (α) on visual quality
after multifocal intraocular lens (IOL) implantation. Setting Eye Hospital, Wenzhou Medical …
after multifocal intraocular lens (IOL) implantation. Setting Eye Hospital, Wenzhou Medical …
Coaxially sighted corneal light reflex versus entrance pupil center centration of moderate to high hyperopic corneal ablations in eyes with small and large angle kappa
DZ Reinstein, M Gobbe… - Journal of Refractive …, 2013 - journals.healio.com
PURPOSE: To determine whether centering ablations on the coaxially sighted corneal light
reflex (CSCLR) in eyes with large angle kappa leads to poor visual outcomes when …
reflex (CSCLR) in eyes with large angle kappa leads to poor visual outcomes when …
Functional optical zone and centration following SMILE and LASIK: a prospective, randomized, contralateral eye study
IB Damgaard, M Ang, AM Mahmoud… - Journal of Refractive …, 2019 - journals.healio.com
PURPOSE: To compare centration and functional optical zone (FOZ) after small incision
lenticule extraction (SMILE) and femtosecond laser–assisted in situ keratomileusis (LASIK) …
lenticule extraction (SMILE) and femtosecond laser–assisted in situ keratomileusis (LASIK) …
Distribution of angle kappa measurements with Orbscan II in a population-based survey
Purpose: To determine the mean angle kappa and its determinants in the population of
Tehran, Iran. Methods: In a cross-sectional survey with random cluster sampling, a total of …
Tehran, Iran. Methods: In a cross-sectional survey with random cluster sampling, a total of …
Centration axis in refractive surgery
SA Mosquera, S Verma, C McAlinden - Eye and Vision, 2015 - Springer
The human eye is an asymmetric optical system and the real cornea is not a rotationally
symmetrical volume. Each optical element in the eye has its own optical and neural axes …
symmetrical volume. Each optical element in the eye has its own optical and neural axes …
Topography-guided hyperopic LASIK with and without high irradiance collagen cross-linking: initial comparative clinical findings in a contralateral eye study of 34 …
AJ Kanellopoulos, J Kahn - Journal of refractive surgery, 2012 - journals.healio.com
PURPOSE: To evaluate the safety and efficacy of intrastromally applied collagen cross-
linking (CXL) in a comparative contralateral eye study of topography-guided femtosecond …
linking (CXL) in a comparative contralateral eye study of topography-guided femtosecond …