[图书][B] Electrical impedance: principles, measurement, and applications
L Callegaro - 2012 - books.google.com
Electrical Impedance: Principles, Measurement, and Applications provides a modern and
much-needed overview of electrical impedance measurement science and its application in …
much-needed overview of electrical impedance measurement science and its application in …
The metrology of electrical impedance at high frequency: a review
L Callegaro - Measurement Science and Technology, 2008 - iopscience.iop.org
The measurement of electrical impedance in the high-frequency range (loosely speaking,
from 100 kHz to 100 MHz) is a common characterization technique in research and …
from 100 kHz to 100 MHz) is a common characterization technique in research and …
Four-terminal-pair impedances and scattering parameters
L Callegaro, F Durbiano - Measurement Science and Technology, 2003 - iopscience.iop.org
The calibration of modern automatic RLC bridges requires a set of impedance standards.
Each standard needs in turn a calibration, ie the knowledge of its four-terminal-pair …
Each standard needs in turn a calibration, ie the knowledge of its four-terminal-pair …
Towards accurate measurement of the frequency dependence of capacitance and resistance standards up to 10 MHz
SA Awan, BP Kibble - IEEE Transactions on Instrumentation …, 2005 - ieeexplore.ieee.org
Progress toward an understanding of the frequency dependence of capacitance and
resistance standards at frequencies up to 10 MHz is presented. A qualitative comparison is …
resistance standards at frequencies up to 10 MHz is presented. A qualitative comparison is …
Analysis of virgin olive oil volatiles by a novel electronic nose based on a miniaturized SAW sensor array coupled with SPME enhanced headspace enrichment
DL García-González, N Barie, M Rapp… - Journal of agricultural …, 2004 - ACS Publications
A novel electronic nose based on solid-phase microextraction (SPME) coupled with a
surface acoustic wave (SAW) sensor array has been used to analyze different quality virgin …
surface acoustic wave (SAW) sensor array has been used to analyze different quality virgin …
Realization of four-terminal-pair capacitors as reference standards of impedance at high frequency using impedance-matrix method
S Singh, S Kumar, T John - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
The four-terminal-pair air capacitors of nominal values 1000 and 100 pF have been realized
as reference standards of impedance upto 10 MHz using impedance-matrix method. The …
as reference standards of impedance upto 10 MHz using impedance-matrix method. The …
A programmable capacitor for inductance measurements
B Waltrip, F Seifert - IEEE Transactions on Instrumentation and …, 2017 - ieeexplore.ieee.org
This paper describes a programmable capacitor intended for use as the reference
impedance in an inductance measurement system. The capacitor is programmable from 1 …
impedance in an inductance measurement system. The capacitor is programmable from 1 …
Evaluation of four-terminal-pair capacitance standards using electrical equivalent circuit model
B Khurana, S Kumar, AK Saxena - Measurement, 2015 - Elsevier
The reported work has been performed in order to establish the measurement traceability of
high frequency capacitance standards at CSIR-NPL. In this context, four-terminal-pair air …
high frequency capacitance standards at CSIR-NPL. In this context, four-terminal-pair air …
A Universal Geometry for Calculable Frequency-Response Coefficient of LCR Standards and New 10-MHz Resistance and 1.6-MHz Quadrature-Bridge Systems
SA Awan, BP Kibble - IEEE Transactions on Instrumentation …, 2007 - ieeexplore.ieee.org
A new four terminal-pair (4TP) coaxial-bridge system for accurate resistance measurements
at frequencies up to 10 MHz has been developed. The deviation of a calculable 4TP 1-kΩ …
at frequencies up to 10 MHz has been developed. The deviation of a calculable 4TP 1-kΩ …
Measurement automation to implement evaluation procedure of four-terminal-pair capacitance standards using S-parameters
The evaluation procedure of four-terminal-pair capacitance standards using S-parameters is
very complex as it involves the measurement of different parameters by multiple instruments …
very complex as it involves the measurement of different parameters by multiple instruments …