[HTML][HTML] Concrete walls weakened by openings as compression members: A review
The purpose of this paper is to review the advances that have been made in the design of
monolithic and precast reinforced concrete walls, both with and without openings, subject to …
monolithic and precast reinforced concrete walls, both with and without openings, subject to …
The effects of CFRP orientation on the strengthening of reinforced concrete structures
In recent years, the strengthening and retrofitting of structural members using externally
bonded carbon fibre reinforced polymer (CFRP) materials has gained a great deal of …
bonded carbon fibre reinforced polymer (CFRP) materials has gained a great deal of …
Ultimate strength analysis of normal and high strength concrete wall panels with varying opening configurations
H Guan, C Cooper, DJ Lee - Engineering Structures, 2010 - Elsevier
Currently the wall panel design equations given in the Australian Standard and the
American Institute Code offer no guidelines for the inclusion of side restraints or openings …
American Institute Code offer no guidelines for the inclusion of side restraints or openings …
Behavior of axially loaded concrete wall panels with openings: an experimental study
S Fragomeni, JH Doh, DJ Lee - Advances in structural …, 2012 - journals.sagepub.com
Forty seven reinforced concrete walls with various opening configurations are tested in both
one-way and two-way action. The test panels, with a slenderness ratio of 30, 35 or 40, were …
one-way and two-way action. The test panels, with a slenderness ratio of 30, 35 or 40, were …
Effect of cut-out openings on the axial strength of concrete walls
Old structures are frequently modified to comply with current living standards and/or
legislation. Such modifications may include the addition of new windows or doors and paths …
legislation. Such modifications may include the addition of new windows or doors and paths …
Ultimate load formula for reinforced concrete wall panels with openings
JH Doh, S Fragomeni - Advances in Structural Engineering, 2006 - journals.sagepub.com
Reinforced concrete walls with openings are tested in both one-way and two-way action.
The test panels, with a slenderness ratio of 30 or 40, were subjected to a uniformly …
The test panels, with a slenderness ratio of 30 or 40, were subjected to a uniformly …
Experimental study on RC walls with opening strengthened by externally bonded CFRP
RC walls with an opening under eccentric axial loads exhibit cracks around the opening
leading to a reduction in the ultimate strength of the wall. These cracks are mainly due to …
leading to a reduction in the ultimate strength of the wall. These cracks are mainly due to …
Effect of opening on the performance of bamboo-reinforced Concrete Wall panels under one-way in-plane action
PR Himasree, N Ganesan, PV Indira - Journal of Architectural …, 2023 - ascelibrary.org
This study focuses on the effect of opening on the performance of bamboo-reinforced
concrete wall panels subjected to one-way in-plane action. The study evaluates the …
concrete wall panels subjected to one-way in-plane action. The study evaluates the …
Bamboo reinforced concrete wall panels under one way in-plane action
N Ganesan, PV Indira, PR Himasree - Environment, Development and …, 2020 - Springer
An experimental study has been carried out to determine the strength and behaviour of
bamboo-reinforced concrete wall panels under one-way in-plane action. Three full-scale …
bamboo-reinforced concrete wall panels under one-way in-plane action. Three full-scale …
[图书][B] Experimental and theoretical studies of normal and high strength concrete wall panels with openings
DJ Lee - 2009 - researchgate.net
The simplified wall design formulae specified in the Australian (AS3600) and American
(ACI318) concrete standards are intended for the design of normal strength concrete load …
(ACI318) concrete standards are intended for the design of normal strength concrete load …