Mechanism of electrical breakdown of gases for pressures from 10− 9 to 1 bar and inter-electrode gaps from 0.1 to 0.5 mm

P Osmokrovic, M Vujisic, K Stankovic… - Plasma Sources …, 2007 - iopscience.iop.org
This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-
electrode gap, ie in the vicinity of the Paschen minimum. In this area of pressure and inter …

Study on insulation characteristics of GIS under combined voltage of DC and lightning impulse

J Ma, Q Zhang, H You, Z Wu, T Wen… - … on Dielectrics and …, 2017 - ieeexplore.ieee.org
Operating experience shows that residual DC voltage remains in GIS bus bar for a long time
after opening of disconnectors. This DC voltage will not only cause accumulation of charges …

Electrical breakdown in the area of transition from gas to vacuum electrical discharge mechanisms

N Kartalović, A Jusić, Č Belić, U Kovačević, VS Mališ… - Vacuum, 2024 - Elsevier
Except for quantum mechanical phenomena, physical phenomena are not prone to sudden
and abrupt changes. In this paper, the transition mechanism from the electric discharge gas …

The influence of parameters of gas-insulated system on the duration of electrical breakdown at points near to Paschen minimum

A Jusić, T Stojić, Đ Lazarević, U Kovačević - Vacuum, 2023 - Elsevier
The paper considers the time of thermoionization of the spark channel during gas
breakdown in the vicinity of Paschen minimum. For the purposes of measuring the time of …

Passive and active shielding against electromagnetic radiation

SB Đekić, DP Nikezić, D Brajović… - Nuclear Technology …, 2020 - vinar.vin.bg.ac.rs
In nuclear physics experiments, it is very important to isolate the measured quantities from
electromagnetic noise. Without this possibility, it is impossible to obtain usable experimental …

Influence of tube volume on measurement uncertainty of GM counters

KĐ Stanković, ML Vujisić, LD Delić - Nuclear Technology and …, 2010 - doiserbia.nb.rs
GM counters are often used in radiation detection since they generate a strong signal which
can be easily detected. The working principal of a GM counter is based on the interaction of …

The influence of the GM tube insulation parameters on the GM counter characteristics

D Arbutina, A Vasić-Milovanović, T Nedić - Vacuum, 2022 - Elsevier
The paper presents the results of testing the Geiger-Muller chamber cathode radii on the GM
counters characteristics. The influence of the cathode radius is tested on: 1-the GM counter …

Experimental verification of the capillary plasma triggered long spark gap under the extremely low working coefficient in air

D Huang, LJ Yang, P Huo, JB Ma, S Liu, W Wang… - Physics of …, 2016 - pubs.aip.org
The paper has proposed a new triggering method for long spark gap based on capillary
plasma ejection and conducted the experimental verification under the extremely low …

Effect of the gap on discharge characteristics of the three-electrode trigatron switch

HH Zhu, L Huang, ZH Cheng, J Yin… - Journal of Applied …, 2009 - pubs.aip.org
A mathematical model was proposed to calculate the breakdown time based on the
theoretical analysis of the discharging mechanism for three-electrode trigatron switch with …

Statistical methods for designing a Geiger–Muller counter suitable for an early warning system

D Arbutina, A Vasić-Milovanović, T Nedić - Nuclear Instruments and …, 2022 - Elsevier
The paper discusses statistical methods that can be applied when constructing the Geiger–
Muller counters to obtain the same response to radiation, regardless of their dimensions …