Control algorithms of shunt active power filter for harmonics mitigation: A review

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2017 - mdpi.com
Current harmonics is one of the most significant power quality issues which has attracted
tremendous research interest. Shunt active power filter (SAPF) is the best solution to …

DC-link capacitor voltage regulation for three-phase three-level inverter-based shunt active power filter with inverted error deviation control

Y Hoon, MA Mohd Radzi, MK Hassan, NF Mailah - Energies, 2016 - mdpi.com
A new control technique known as inverted error deviation (IED) control is incorporated into
the main DC-link capacitor voltage regulation algorithm of a three-level neutral-point diode …

Active power filtering under unbalanced and distorted grid conditions using modular fundamental element detection technique

Y Hoon, MAAM Zainuri, AS Al-Ogaili, AN Al-Masri… - IEEE …, 2021 - ieeexplore.ieee.org
In this paper, an alternative control technique for producing reference current signal to
manage operation of three-phase three-wire parallel-connected active power filter (PAPF) is …

comparative analysis of power quality using PD & PID controller of hybrid power system

A Nigam, KK Sharma - … on Trends in Electronics and Informatics …, 2022 - ieeexplore.ieee.org
In these days power quality is an important issue for grid integrated with different energy
sources. For energy demand hybrid renewable energy sources play a vital to fulfill energy …

[PDF][PDF] Dc-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter

N Farzilah, YH Mailah, M Amran… - Pertanika Journal of …, 2017 - pertanika.upm.edu.my
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its
controller, DC-link capacitor voltage regulation algorithm with either proportional-integral …

[PDF][PDF] Harmonic Reduction by Using Shunt Hybrid Power Filter

K Dewangan, PC Tapre - International Journal of Computational …, 2014 - academia.edu
This project report presents design, simulation and development of passive shunt filter and
shunt hybrid power filter (SHPF) for mitigation of the power quality problem at ac mains in ac …

[PDF][PDF] Reactive Power Compensation on 132 KV Substation Using Soft Computing Techniques (Fuzzy Logic)

Y Saratkar, A Pachori - International Journal of Advanced Computer …, 2013 - Citeseer
In this paper we proposes an automated solution based on fuzzy controller to switch
capacitor banks where in which all the decisions are based on the actual data points such …

Double tuned resonant filter used transformer less grid connected photovoltaic system

PK Pranav, PN Korde - 2016 International Conference on …, 2016 - ieeexplore.ieee.org
Now a days, renewable of energy of different sources is attracted the various researchers
and investors for the research work. The photovoltaic system is the best example of the …

[PDF][PDF] Reactive Power Compensation in Transmission Line using Fuzzy Control Method: A Survey

Y Saratkar, A Pachori - Int. J. Adv. Comput. Res, 2013 - Citeseer
If we discuss about the capacitor allocation strategy, then there are several factors like time,
allocation size, distribution feeder comes in our mind. Static VAR Compensator (SVC) is a …

INVESTIGATION ON HARMONIC PROBLEMS FOR N-1 CONTINGENCY IN INDUSTRIAL DISTRIBUTION AND MITIGATION USING FUZZY CONTROLLED HYBRID …

SM GHULBET - 2018 - ir.jkuat.ac.ke
The electric distribution structure of modern industries is rapidly changing and becomes
complex and complex as a result of an increase in demand and market competition …