High-Accuracy Line Intensities Determined from Theory and Experiment
Atmospheric CO 2 concentrations are being closely monitored by remote sensing
experiments which rely on knowing line intensities with an uncertainty of 0.5% or better …
experiments which rely on knowing line intensities with an uncertainty of 0.5% or better …
Line shapes, positions and intensities of water transitions near 1.28 μm
VT Sironneau, JT Hodges - Journal of Quantitative Spectroscopy and …, 2015 - Elsevier
We present measurements of approximately 70 isolated, self-broadened, water vapor lines
which are assigned to the (1, 0, 1)–(0, 0, 0),(0, 0, 2)–(0, 0, 0),(1, 2, 0)–(0, 0, 0), and (2, 0, 0) …
which are assigned to the (1, 0, 1)–(0, 0, 0),(0, 0, 2)–(0, 0, 0),(1, 2, 0)–(0, 0, 0), and (2, 0, 0) …
Absolute molecular transition frequencies measured by three cavity-enhanced spectroscopy techniques
Absolute frequencies of unperturbed 12 C 16 O transitions from the near-infrared (3–0) band
were measured with uncertainties five-fold lower than previously available data. The …
were measured with uncertainties five-fold lower than previously available data. The …
Cavity ring-down spectrometer for high-fidelity molecular absorption measurements
H Lin, ZD Reed, VT Sironneau, JT Hodges - Journal of Quantitative …, 2015 - Elsevier
We present a cavity ring-down spectrometer which was developed for near-infrared
measurements of laser absorption by atmospheric greenhouse gases. This system has …
measurements of laser absorption by atmospheric greenhouse gases. This system has …
[HTML][HTML] Theoretically predicted CO2 lines near 700 nm not observed
AA Balashov, A Raj, S Wójtewicz, R Ciuryło… - Journal of Quantitative …, 2024 - Elsevier
We present an experimental study of carbon dioxide absorption in the transparency window
near 700 nm, where different calculations predicted several extremely weak bands. The …
near 700 nm, where different calculations predicted several extremely weak bands. The …
Optically switched dual-wavelength cavity ring-down spectrometer for high-precision isotope ratio measurements of methane δd in the near infrared
We report a spectrometer employing optically switched dual-wavelength cavity ring-down
spectroscopy (OSDW-CRDS) for high-precision measurements of methane isotope ratios. A …
spectroscopy (OSDW-CRDS) for high-precision measurements of methane isotope ratios. A …
Electric-Force Conversion Performance of Si-Based LiNbO3 Devices Based on Four Cantilever Beams
H Zhang, X Qiao, H Wei, X Li, X Wu, N Yu, H Lu, T Guo… - Micromachines, 2023 - mdpi.com
In micron or nano smart sensing systems, piezoelectric cantilever beams are distributed as
major components in microsensors, actuators, and energy harvesters. This paper …
major components in microsensors, actuators, and energy harvesters. This paper …
Continuous-wave frequency-shifted interferometry cavity ring-down gas sensing with differential optical absorption
H Tian, CM Zhou, D Fan, YW Ou, T Tian… - IEEE Photonics …, 2015 - ieeexplore.ieee.org
This paper proposes a novel frequency-shifted interferometry (FSI) fiber cavity ring-down
(CRD) gas sensing with dual-wavelength differential optical absorption that requires no …
(CRD) gas sensing with dual-wavelength differential optical absorption that requires no …
Frequency-locked cavity ring-down Faraday rotation spectroscopy
Cavity ring-down Faraday rotation spectroscopy (CRD-FRS) is a technique for trace gas
measurements of paramagnetic species that retrieves the molecular concentration from the …
measurements of paramagnetic species that retrieves the molecular concentration from the …
Precise cavity enhanced absorption spectroscopy
A short review of recent achievements in high-precision cavity enhanced absorption
spectroscopy is presented. Actual challenges and development paths in modern line shape …
spectroscopy is presented. Actual challenges and development paths in modern line shape …