Experimental data and numerical modelling of 1.3 and 2.3 MW fires in a 20 m cubic atrium
C Gutiérrez-Montes, E Sanmiguel-Rojas… - Building and …, 2009 - Elsevier
Atria and large spaces are common architectonical features in modern buildings such as
high rises, auditoria, warehouses, airports and mass transport stations among others. There …
high rises, auditoria, warehouses, airports and mass transport stations among others. There …
Sustainable smoke extraction system for atrium: A numerical study
Smoke extraction systems, either static with natural ventilation, or dynamic with mechanical
ventilation are required to keep smoke layer at high levels in many tall atria. It is observed …
ventilation are required to keep smoke layer at high levels in many tall atria. It is observed …
Numerical simulation of an experimental atrium fires in combined natural and forced ventilation by CFD
MM Barsim, MA Bassily, HM El-Batsh… - … Journal of Ventilation, 2020 - Taylor & Francis
This study investigates the measurements data attained in Murcia Atrium fire tests (Gutiérrez-
Montes, Sanmiguel-Rojas, Viedma, & Rein) using general CFD code, CFX-16.2 (CFX-16.2 …
Montes, Sanmiguel-Rojas, Viedma, & Rein) using general CFD code, CFX-16.2 (CFX-16.2 …
Using helium smoke as a surrogate of fire smoke for the study of atrium smoke filling
This study developed a method of using pure helium to generate a cold buoyant plume as
the surrogate of a fire smoke for the study of the smoke-filling process in an atrium. Aided by …
the surrogate of a fire smoke for the study of the smoke-filling process in an atrium. Aided by …
Numerical study on smoke movement driven by pure helium in atria
LL Wang, G Zhao - Fire safety journal, 2013 - Elsevier
The hot smoke test is often used for commissioning fire smoke management system in
atrium buildings, in which liquid fuel is burnt to generate a buoyant plume mixed with …
atrium buildings, in which liquid fuel is burnt to generate a buoyant plume mixed with …
Froude scaling modeling in an Atrium Fire equipped with natural and transient forced ventilation
MM Barsim, MA Bassily, HM El-Batsh… - … Journal of Ventilation, 2020 - Taylor & Francis
In this paper, the capability of Froude scaling modeling to replicate the fire dynamics in full-
scale Murcia Atrium Fires tests equipped with natural and transient forced ventilation was …
scale Murcia Atrium Fires tests equipped with natural and transient forced ventilation was …
Investigation on Smoke Flow in Stairwells induced by an Adjacent Compartment Fire in High Rise Buildings
The aim of this study was to evaluate the transport phenomena of smoke flow and vertical
temperature distribution in a 21-story stairwell with multiple fire locations and openings. A …
temperature distribution in a 21-story stairwell with multiple fire locations and openings. A …
Scale modeling on natural smoke filling in an atrium
WK Chow, HHW Lo - Heat Transfer Engineering, 2008 - Taylor & Francis
Scale-modeling on atrium smoke movement is presented in this paper. Experiments on
natural smoke filling process with diesel pool fires were carried out at a full-scale atrium …
natural smoke filling process with diesel pool fires were carried out at a full-scale atrium …
Инженерный метод выбора рационального варианта противопожарной защиты объектов с экономической ответственностью
ВИ Присадков, СВ Муслакова… - …, 2016 - cyberleninka.ru
На основе критерия приведенных затрат и стохастических представлений о пожарах
разраотаны теоретические основы выбора экономически целесообразных вариантов …
разраотаны теоретические основы выбора экономически целесообразных вариантов …
On the operation time of horizontal ceiling vent in an atrium
YZ Li, R Huo, WK Chow - Journal of fire sciences, 2002 - journals.sagepub.com
Smoke control by a horizontal ceiling vent in an atrium is studied in this paper. A bi-
directional airflow moving upward and downward across the vent might be observed and …
directional airflow moving upward and downward across the vent might be observed and …