HVDC transmission: Technology review, market trends and future outlook

A Alassi, S Bañales, O Ellabban, G Adam… - … and Sustainable Energy …, 2019 - Elsevier
HVDC systems are playing an increasingly significant role in energy transmission due to
their technical and economic superiority over HVAC systems for long distance transmission …

Stability and control of mixed AC–DC systems with VSC‐HVDC: a review

R Shah, JC Sánchez, R Preece… - IET Generation …, 2018 - Wiley Online Library
Voltage‐source converter‐high‐voltage direct current (VSC‐HVDC) systems have become
an attractive option for integrating remote and far‐from‐shore renewable energy resources …

Improved weak grids synchronization unit for passivity enhancement of grid-connected inverter

X Lin, Y Wen, R Yu, J Yu, H Wen - IEEE Journal of Emerging …, 2022 - ieeexplore.ieee.org
The weak grids may be unstable due to the negative resistance behavior of the grid-
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …

Constant-coupling-effect-based PLL for synchronization stability enhancement of grid-connected converter under weak grids

X Lin, R Yu, J Yu, H Wen - IEEE Transactions on Industrial …, 2022 - ieeexplore.ieee.org
The phase-locked loop (PLL)-caused couplings on the grid-connected converter (GCC) are
strengthened by increasing its bandwidth and then incur synchronization instability. This …

Impact of power grid strength and PLL parameters on stability of grid-connected DFIG wind farm

J Liu, W Yao, J Wen, J Fang, L Jiang… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
This paper investigates the impact of powergrid strength and phase-locked loop (PLL)
parameters on small signal stability of grid-connected doubly fed induction generator (DFIG) …

Nonlinear and transient stability analysis of phase-locked loops in grid-connected converters

J Zhao, M Huang, H Yan, KT Chi… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
The undesired nonlinear operation of phase-locked loops (PLL) is one of the main causes of
transient instability in grid-connected converters. However, the stable operating region of …

Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid

D Zhu, S Zhou, X Zou, Y Kang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …

Improving small-signal stability of grid-connected inverter under weak grid by decoupling phase-lock loop and grid impedance

X Lin, J Yu, R Yu, J Zhang, Z Yan… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
The wide bandwidth of phase-locked loop (PLL) will increase the negative real part of the
output impedance of the grid-connected inverter (GCI), thus destroying the stability of the …

Analysis of modal resonance between PLL and DC-link voltage control in weak-grid tied VSCs

D Wang, L Liang, L Shi, J Hu… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Weak ac grid operation is known to challenge the stability of voltage source converters
(VSCs). This paper provides an interpretation for the cause of such instability in view of a …

Impedance analysis of virtual synchronous generator-based vector controlled converters for weak AC grid integration

A Asrari, M Mustafa, M Ansari… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Voltage source converter (VSC) based high-voltage direct current (hVDC) system is an
emerging technology in high-power applications. Previous research has shown that VSCs …