HVDC transmission: Technology review, market trends and future outlook
HVDC systems are playing an increasingly significant role in energy transmission due to
their technical and economic superiority over HVAC systems for long distance transmission …
their technical and economic superiority over HVAC systems for long distance transmission …
Stability and control of mixed AC–DC systems with VSC‐HVDC: a review
Voltage‐source converter‐high‐voltage direct current (VSC‐HVDC) systems have become
an attractive option for integrating remote and far‐from‐shore renewable energy resources …
an attractive option for integrating remote and far‐from‐shore renewable energy resources …
Improved weak grids synchronization unit for passivity enhancement of grid-connected inverter
The weak grids may be unstable due to the negative resistance behavior of the grid-
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …
connected inverter (GCI) caused by the synchronization unit with the phase-locked loop …
Constant-coupling-effect-based PLL for synchronization stability enhancement of grid-connected converter under weak grids
The phase-locked loop (PLL)-caused couplings on the grid-connected converter (GCC) are
strengthened by increasing its bandwidth and then incur synchronization instability. This …
strengthened by increasing its bandwidth and then incur synchronization instability. This …
Impact of power grid strength and PLL parameters on stability of grid-connected DFIG wind farm
This paper investigates the impact of powergrid strength and phase-locked loop (PLL)
parameters on small signal stability of grid-connected doubly fed induction generator (DFIG) …
parameters on small signal stability of grid-connected doubly fed induction generator (DFIG) …
Nonlinear and transient stability analysis of phase-locked loops in grid-connected converters
The undesired nonlinear operation of phase-locked loops (PLL) is one of the main causes of
transient instability in grid-connected converters. However, the stable operating region of …
transient instability in grid-connected converters. However, the stable operating region of …
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
Improving small-signal stability of grid-connected inverter under weak grid by decoupling phase-lock loop and grid impedance
X Lin, J Yu, R Yu, J Zhang, Z Yan… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
The wide bandwidth of phase-locked loop (PLL) will increase the negative real part of the
output impedance of the grid-connected inverter (GCI), thus destroying the stability of the …
output impedance of the grid-connected inverter (GCI), thus destroying the stability of the …
Analysis of modal resonance between PLL and DC-link voltage control in weak-grid tied VSCs
Weak ac grid operation is known to challenge the stability of voltage source converters
(VSCs). This paper provides an interpretation for the cause of such instability in view of a …
(VSCs). This paper provides an interpretation for the cause of such instability in view of a …
Impedance analysis of virtual synchronous generator-based vector controlled converters for weak AC grid integration
Voltage source converter (VSC) based high-voltage direct current (hVDC) system is an
emerging technology in high-power applications. Previous research has shown that VSCs …