Corona detection and power equipment classification based on GoogleNet-AlexNet: An accurate and intelligent defect detection model based on deep learning for …
N Davari, G Akbarizadeh… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
This paper presents a deep learning-based method for defect detection and classification of
power distribution lines using video analysis. The first stage is dataset preparation in which …
power distribution lines using video analysis. The first stage is dataset preparation in which …
Ensuring the structural safety of overhead transmission lines by design
JX Li, G McClure, SH Wang - Journal of Aerospace Engineering, 2021 - ascelibrary.org
During service, transmission lines (TLs) will be subjected to unbalanced longitudinal loads
due to events such as conductor breakage, insulator failure, and sudden ice shedding …
due to events such as conductor breakage, insulator failure, and sudden ice shedding …
Potential of slippery liquid infused porous surface coatings as flashover inhibitors on porcelain insulators in icing, contaminated, and harsh environments
A Olad, F Maryami, A Mirmohseni… - Progress in Organic …, 2021 - Elsevier
Humidity and pollution deposition on the surface of porcelain insulators affect the electrical
field distribution and their performance which may lead to partial discharge and decreasing …
field distribution and their performance which may lead to partial discharge and decreasing …
Advanced Diagnostic Approach for High-Voltage Insulators: Analyzing Partial Discharges through Zero-Crossing Rate and Fundamental Frequency Estimation of …
K Maresch, LF Freitas-Gutierres, AL Oliveira, AS Borin… - Energies, 2023 - mdpi.com
Acoustic inspection is a valuable technique that can detect early stage defects in equipment,
thereby facilitating predictive maintenance. In recent times, ultrasonic sensors have made …
thereby facilitating predictive maintenance. In recent times, ultrasonic sensors have made …
Non-destructive analysis of power insulators by frequency response function and three dimensional-computed tomography
Various techniques are being implemented to analyze outdoor insulators. It plays an
important role in the transmission line, and its electrical insulation and mechanical support …
important role in the transmission line, and its electrical insulation and mechanical support …
Study on the discharge characteristic and detection method on the faulty of distribution insulators
LJ Zhou, Y Tian, WJ Chen, S Ling, Z Fu… - … Materials and Power …, 2019 - ieeexplore.ieee.org
The porcelain insulators are widely used in distribution network of China. In order to attach
overhead cables on it, the binding wires are used. As the binding wires are bonded on the …
overhead cables on it, the binding wires are used. As the binding wires are bonded on the …
Study on the Mechanism and Electrical Characterization of the Distribution Porcelain Insulator Incipient Fault in the Non-Effectively Grounded System
Z Cong, Y Liu, Y Yan, K Wang… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
The porcelain insulator incipient fault (PIIF) is a self-clearing discharge process caused by
water entering the crack of the porcelain insulator. It will not result in a tripping operation but …
water entering the crack of the porcelain insulator. It will not result in a tripping operation but …
Analysis of cement deterioration in outdoor high-voltage insulator
T Kim, S Sanyal, JB Koo, JA Son, IH Choi, J Yi - Materials, 2019 - mdpi.com
Suspension type porcelain insulators used in overhead transmission lines comprise metal,
ceramic, and cement. The deterioration of cement can lead to mechanical separation. For …
ceramic, and cement. The deterioration of cement can lead to mechanical separation. For …
Dynamic response of tower-line system induced by insulator breakage considering the collision between the conductor and the ground surface
JX Li, SH Wang, X Fu - Journal of Performance of Constructed …, 2020 - ascelibrary.org
Insulator fatigue, lighting strike, or flashover could result in the breakage of insulator strings.
Insulator breakage can cause conductor impingement on the ground, which is a threat to the …
Insulator breakage can cause conductor impingement on the ground, which is a threat to the …
Study on partial discharge fault diagnosis of high voltage switchboard based on ultrasound detection
M Liu, Z Li, P Qiu - Journal of Physics: Conference Series, 2022 - iopscience.iop.org
In view of the problem that the partial discharge type of switchgear still needs to be judged
by the staff according to the collected phase diagram and experience after the erection of …
by the staff according to the collected phase diagram and experience after the erection of …