Instrumentation at the leading edge of proteomics
The proteome, or collection of proteoforms expressed in a biological system, is dynamic and
heterogeneous. As our appreciation for the complexity of the proteome has evolved, so have …
heterogeneous. As our appreciation for the complexity of the proteome has evolved, so have …
Adaptation and operation of a quadrupole/time-of-flight tandem mass spectrometer for high mass ion/ion reaction studies
JS Bhanot, KC Fabijanczuk, AM Abdillahi… - International journal of …, 2022 - Elsevier
A commercial quadrupole/time-of-flight tandem mass spectrometer has been modified and
evaluated for its performance in conducting ion/ion reaction studies involving high mass (> …
evaluated for its performance in conducting ion/ion reaction studies involving high mass (> …
Digital quadrupole isolation and electron capture dissociation on an extended mass range Q-TOF provides sequence and structure information on proteins and …
C Lantz, R Schrader, J Meeuwsen, J Shaw… - Journal of the …, 2023 - ACS Publications
Electron capture dissociation (ECD) is now a well-established method for sequencing
peptides and performing top-down analysis on proteins of less than 30 kDa, and there is …
peptides and performing top-down analysis on proteins of less than 30 kDa, and there is …
Top-down mass spectrometry of native proteoforms and their complexes: a community study
The combination of native electrospray ionization with top-down fragmentation in mass
spectrometry (MS) allows simultaneous determination of the stoichiometry of noncovalent …
spectrometry (MS) allows simultaneous determination of the stoichiometry of noncovalent …
Optimization of a Digital Mass Filter for the Isolation of Intact Protein Complexes in Stability Zone 1, 1
Digital mass filters are advantageous for the analysis of large molecules due to the ability to
perform ion isolation of high-m/z ions without the generation of very high radio frequency …
perform ion isolation of high-m/z ions without the generation of very high radio frequency …
Commissioning the digital mass-filter/ion-trap module for the MS SPIDOC prototype
F Simke, P Fischer, T Damjanović… - Journal of …, 2023 - iopscience.iop.org
The combination of a linear quadrupole ion-filter and linear Paul trap operated with a
rectangular guiding field for the filtering and accumulation of ions within the Mass …
rectangular guiding field for the filtering and accumulation of ions within the Mass …
Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation
GC Roesch, E Garand - The Journal of Physical Chemistry A, 2023 - ACS Publications
We present the implementation of tandem mass-selective cryogenic ion traps, designed to
enhance the range of ion processing capabilities that can be performed prior to …
enhance the range of ion processing capabilities that can be performed prior to …
Increasing Isolation Efficiency Using a Segmented Quadrupole Mass Filter Operated with Rectangular Waveforms
RL Schrader, GA Anderson… - Journal of the American …, 2024 - ACS Publications
The performance of a segmented quadrupole mass filter operated with rectangular
waveforms and capacitively coupled rectangular waveforms applied to the prefilters was …
waveforms and capacitively coupled rectangular waveforms applied to the prefilters was …
Petroleomics by design of experiments in ESI (±) FT-ICR MS analysis
GS Folli, L dos Santos, MP Zanoni, LSC Junior… - Fuel, 2024 - Elsevier
Abstract The Fourier Transform Ion Cyclotron Resonance mass spectrometer (FT-ICR MS) is
an efficient and widely used analytical instrument for characterizing complex organic …
an efficient and widely used analytical instrument for characterizing complex organic …
Experimental Evaluation of Higher Order Stability Zones Using a Digitally Operated Quadrupole Mass Filter
S Chakravorty, E Groetsema, FO Obe… - Journal of the …, 2024 - ACS Publications
Recent improvements to the comparison-based method of digital waveform generation
increased the reproducibility of the waveforms so that the higher-order Mathieu stability …
increased the reproducibility of the waveforms so that the higher-order Mathieu stability …