Flexible PZT thin film tactile sensor for biomedical monitoring

HJ Tseng, WC Tian, WJ Wu - Sensors, 2013 - mdpi.com
This paper presents the development of tactile sensors using the sol-gel process to deposit
a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film …

Electrically insulated sensing of respiratory rate and heartbeat using optical fibers

E Suaste-Gómez, D Hernández-Rivera… - Sensors, 2014 - mdpi.com
Respiratory and heart rates are among the most important physiological parameters used to
monitor patients' health. It is important to design devices that can measure these parameters …

P (VDF-TrFE) polymer-based thin films deposited on stainless steel substrates treated using water dissociation for flexible tactile sensor development

HJ Tseng, WC Tian, WJ Wu - Sensors, 2013 - mdpi.com
In this work, deionized (DI) water dissociation was used to treat and change the contact
angle of the surface of stainless steel substrates followed by the spin coating of P (VDF …

[PDF][PDF] Non invasive measurement of systolic blood pressure in rats: a simple technique

M Pauline, ST Avadhany… - Al Ameen Journal of …, 2011 - ajms.alameenmedical.org
Background: Non invasive, simple and economical instrument to measure blood pressure in
r365-ats is important in cardiovascular research. Methods: Systolic blood pressure …

Multiple time and spectral analysis techniques for comparing the PhotoPlethysmography to PiezoelectricPlethysmography with electrocardiography

AM Alqudah, Q Qananwah, AMK Dagamseh… - Medical …, 2020 - Elsevier
Photoplethysmography (PPG) is an important, non-invasive and widely used circulatory
assessment technique. It is commonly used to measure heart rate and arterial oxygen …

Effect of a Metallic Implant on the Hysteresis of Ferroelectric BaTiO3 Ceramics

NA García-Morales… - Ferroelectrics Letters …, 2023 - Taylor & Francis
The dielectric constant and hysteresis loops of BaTiO3 ceramics with and without Pt implants
were compared to determine the effect of the implant on the ceramic behavior. Ceramics …

A PLZT novel sensor with Pt implanted for biomedical application: Cardiac micropulses detection on human skin

CO González-Morán… - … in Materials Science …, 2017 - Wiley Online Library
Advances in sensors for biomedical applications have been a great motivation. In this
research, a PLZT (lead lanthanum zirconate titanate) novel sensor with platinum wire …

Development of Novel Lead-Free Ceramic Electrodes for the Acquisition of Bioelectric Potentials

OEA Mejía, ES Gómez… - 2024 21st International …, 2024 - ieeexplore.ieee.org
Recently, experiments were conducted with potassium niobate (KNbO 3) ceramics, a lead-
free material that possesses ferroelectric and piezoelectric properties, among others, by …

Developed of a Ceramic-Controlled Piezoelectric of Single Disk for Biomedical Applications

ES Gómez, JJAF Cuautle… - … Engineering: Trends in …, 2011 - books.google.com
One of the main topical problems that biomedical discipline has the develop of medical
equipment, prosthesis, diagnostically and therapy equipment, and the others. In the last field …

[HTML][HTML] Piezoelectric ceramic controlled with platinum implant as new isolator in ECG

E Suaste-Gómez, COG Morán… - Materials Sciences and …, 2014 - scirp.org
Recently, a new PLZT bulk single plate, called ceramic-controlled piezoelectric with two
Platinum wires (CCP2) has been produced; this CCP2 has two (250 μm of diameter and 1 …