French Hip & Knee Society classification of short-stem hip prostheses: inter-and intra-observer reproducibility

R Erivan, G Villatte, J Dartus, P Mertl, P Piriou… - … & Traumatology: Surgery …, 2022 - Elsevier
Introduction In total hip replacement (THR), a short stem theoretically provides more
physiological force transfer to the proximal femur, conserves bone stock and facilitates …

Biomechanical study of different bone cement distribution on osteoporotic vertebral compression Fracture-A finite element analysis

C Zhou, X Meng, S Huang, H Chen, H Zhou, Y Liao… - Heliyon, 2024 - cell.com
Purpose This study aimed to compare the biomechanical effects of different bone cement
distribution methods on osteoporotic vertebral compression fractures (OVCF). Patients and …

[HTML][HTML] Acute Periprosthetic Hip Fractures with Short, Uncemented Femoral Stems

P Staunton, K Alhojailan, C Desgagne, L Epure… - The Journal of …, 2024 - Elsevier
Background Uncemented femoral stems in hip arthroplasty have shown excellent long-term
results, and several systematic studies indicate satisfactory performance of short stems …

Stress reduction through cortical bone thickening improves bone mechanical behavior in adult female Beclin-1+/− mice

J Yang, Q Pei, X Wu, X Dai, X Li, J Pan… - … in Bioengineering and …, 2024 - frontiersin.org
Fragility fractures, which are more prevalent in women, may be significantly influenced by
autophagy due to altered bone turnover. As an essential mediator of autophagy, Beclin-1 …

Callus formation after total hip arthroplasty using a short tapered-wedge stem

S Ishii, T Baba, Y Shirogane, K Hayashi, Y Homma… - Skeletal Radiology, 2024 - Springer
Objective The incidence of periprosthetic fractures after total hip arthroplasty using a short
tapered-wedge stem is high. Callus formation preceding this fracture, which indicates …

Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce

Z Xiao, L Wu, W Wu, R Tang, J Dai, D Zhu - Materials, 2023 - mdpi.com
Hip replacement femoral implants are made of substantial materials that all have stiffness
considerably higher than that of bone, which can cause significant bone resorption …

加载方式对股骨柄头颈部应力分布的影响

谢菲, 贾鹏, 刘佳辛, 刘璐, 张春秋, 叶金铎 - 中国组织工程研究, 2022 - cjter.com
加载方式对股骨柄头颈部应力分布的影响 Page 1 2302|中国组织工程研究|第26卷|第15期|2022年
5月 中国组织工程研究 Chinese Journal of Tissue Engineering Research www.CJTER.com …

A Time-Dependent Design Concept of a Cementless Hip Stem Prosthesis for Improving Physiological Load Transfer in Proximal Femur: A Finite Element Analysis

CC Huang, CK Cheng, HW Wei - Journal of Medical and Biological …, 2022 - Springer
Purpose Although short-stem prostheses have been introduced to improve metaphyseal
load transmission, the shortcomings of short-stem total hip arthroplasties (THAs) such as …

Effect of short stem alignment on initial fixation, stress transfer, and failure risk

Y Yabusaki, K Asai, H Hisakado… - Technology and Health …, 2024 - content.iospress.com
BACKGROUND: Short stems are advantageous for revision as they preserve autogenous
bone. At present, the method of short-stem installation is determined based on the surgeon's …

CORR Insights®: Are There Differences in Performance Among Femoral Stem Brands Utilized in Cementless Hemiarthroplasty for Treatment of Geriatric Femoral …

JA Keeney - Clinical Orthopaedics and Related Research®, 2022 - journals.lww.com
It is clear that cemented femoral implant fixation for hemiarthroplasty of intracapsular
proximal femur fractures is superior to cementless fixation in terms of overall revision risk …