Recent advances in radiation therapy and photodynamic therapy
In the past 100 years, external beam energy for the treatment of cancer has continually
evolved. Two main modes have been developed. The first is radiotherapy which involves …
evolved. Two main modes have been developed. The first is radiotherapy which involves …
New Limit for Neutrinoless Double-Beta Decay of from the CUPID-Mo Experiment
E Armengaud, C Augier, AS Barabash, F Bellini… - Physical review …, 2021 - APS
The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a
demonstrator for CUPID, the next-generation ton-scale bolometric 0 ν β β experiment. It …
demonstrator for CUPID, the next-generation ton-scale bolometric 0 ν β β experiment. It …
The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research
Purpose This paper covers recent developments and applications of the TOPAS TOol for
PArticle Simulation and presents the approaches used to disseminate TOPAS. Materials and …
PArticle Simulation and presents the approaches used to disseminate TOPAS. Materials and …
Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group
Background Geant4 is a Monte Carlo code extensively used in medical physics for a wide
range of applications, such as dosimetry, micro‐and nanodosimetry, imaging, radiation …
range of applications, such as dosimetry, micro‐and nanodosimetry, imaging, radiation …
Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4
L Grevillot, T Frisson, D Maneval, N Zahra… - Physics in Medicine …, 2011 - iopscience.iop.org
Abstract The GEANT4-based GATE Monte Carlo (MC) platform was initially focused on PET
and SPECT simulations. The new release v6. 0 (February 2010) proposes new tools …
and SPECT simulations. The new release v6. 0 (February 2010) proposes new tools …
Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: dose and IAEA‐compliant phase space calculations
M Constantin, J Perl, T LoSasso, A Salop… - Medical …, 2011 - Wiley Online Library
Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian
TrueBeam treatment head geometry imported from cad (computer aided design) without …
TrueBeam treatment head geometry imported from cad (computer aided design) without …
[PDF][PDF] Recent improvements in geant4 electromagnetic physics models and interfaces
V Ivanchenko, J Apostolakis, A Bagulya… - Progress in nuclear …, 2011 - academia.edu
An overview of the electromagnetic (EM) physics of the Geant4 toolkit is presented. Two sets
of EM models are available: the" Standard" initially focused on high energy physics (HEP) …
of EM models are available: the" Standard" initially focused on high energy physics (HEP) …
A review of electron–nucleus bremsstrahlung cross sections between 1 and 10 MeV
A Mangiarotti, MN Martins - Radiation Physics and Chemistry, 2017 - Elsevier
More than 80 years have passed since the first calculations of electron–nucleus
bremsstrahlung cross sections were published by Sommerfeld, for non-relativistic electrons …
bremsstrahlung cross sections were published by Sommerfeld, for non-relativistic electrons …
Ultrahigh dose-rate (FLASH) x-ray irradiator for pre-clinical laboratory research
M Rezaee, I Iordachita, JW Wong - Physics in Medicine & Biology, 2021 - iopscience.iop.org
FLASH irradiation has been shown to reduce significantly normal tissue toxicity compared to
conventional irradiation, while maintaining tumor control probability at similar level. Clinical …
conventional irradiation, while maintaining tumor control probability at similar level. Clinical …
Monte Carlo simulation of TrueBeam flattening‐filter‐free beams using Varian phase‐space files: comparison with experimental data
MF Belosi, M Rodriguez, A Fogliata, L Cozzi… - Medical …, 2014 - Wiley Online Library
Purpose: Phase‐space files for Monte Carlo simulation of the Varian TrueBeam beams have
been made available by Varian. The aim of this study is to evaluate the accuracy of the …
been made available by Varian. The aim of this study is to evaluate the accuracy of the …