Overview of fluence-to-effective dose and fluence-to-ambient dose equivalent conversion coefficients for high energy radiation calculated using the FLUKA code

M Pelliccioni - Radiation Protection Dosimetry, 2000 - academic.oup.com
ICRP 74 and ICRU 57 recommended conversion coefficients for use in radiological
protection for electrons and photons of energies up to 10 MeV and for neutrons up to 180 …

Calculation of the radiation environment caused by galactic cosmic rays for determining air crew exposure

A Ferrari, M Pelliccioni, T Rancati - Radiation protection …, 2001 - academic.oup.com
The spectra of secondary particles resulting from interactions of primary galactic cosmic rays
with the nuclei in the atmosphere have been calculated using the Monte Carlo transport …

Fluence to effective dose conversion coefficients for neutrons up to 10 TeV

A Ferrari, M Pelliccioni, M Pillon - Radiation Protection …, 1997 - academic.oup.com
Effective dose per unit neutron fluence has been calculated by the FLUKA code for various
geometrical conditions or irradiation of an anthropomorphic phantom placed in a vacuum …

Temporal and spatial evolution of the solar energetic particle event on 20 January 2005 and resulting radiation doses in aviation

D Matthiä, B Heber, G Reitz, M Meier… - Journal of …, 2009 - Wiley Online Library
The solar energetic particle event on 20 January 2005 was one of the largest ground level
events ever observed. Neutron monitor stations in the Antarctic recorded count rate …

Fluence to dose equivalent conversion data and effective quality factors for high energy neutrons

A Ferrari, M Pelliccioni - Radiation Protection Dosimetry, 1998 - academic.oup.com
Calculations of conversion coefficients from fluence to ambient dose equivalent and from
fluence to maximum dose equivalent, along the principal axis of the ICRU sphere, have …

Aircrew exposure from cosmic radiation on commercial airline routes

BJ Lewis, MJ McCall, AR Green… - Radiation protection …, 2001 - academic.oup.com
As a result of the recent recommendations of the ICRP 60, and in anticipation of possible
regulation on occupational exposure of Canadian-based aircrew, an extensive study was …

Fluence to effective dose conversion coefficients for protons from 5 MeV to 10 TeV

A Ferrari, M Pelliccioni, M Pillon - Radiation protection …, 1997 - academic.oup.com
Conversion coefficients from proton fluence to effective dose have been calculated by the
FLUKA code for various geometrical conditions of irradiation of an anthropomorphic …

Boron-loaded polymeric sensor for the direct detection of thermal neutrons

P Chatzispyroglou, JL Keddie… - ACS applied materials & …, 2020 - ACS Publications
We report the first demonstration of a solid-state, direct-conversion sensor for thermal
neutrons based on a polymer/inorganic nanocomposite. Sensors were fabricated from …

[PDF][PDF] deq99. fA FLUKA user-routine converting fluence into effective dose and ambient dose equivalent

S Roesler, GR Stevenson - CERN Technical Note …, 2006 - zeus.phys.uconn.edu
Conversion coefficients from fluence into effective dose and ambient dose equivalent are
implemented as a FLUKA user-routine for incident neutrons, protons, charged pions, muons …

Galactic and solar radiation exposure to aircrew during a solar cycle

B J. Lewis, L GI Bennett, A R. Green… - Radiation protection …, 2002 - academic.oup.com
An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been
carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of …