Recognition of the importance of embolization in atherosclerotic vascular disease
were identified at relatively high frequency (compared with control subjects or patients with
effort angina) in the peripheral blood. 14 Using an experimental canine model, Eguchi et …
effort angina) in the peripheral blood. 14 Using an experimental canine model, Eguchi et …
Prevention and treatment of thromboembolic and ischemic complications associated with endovascular procedures: Part II—Clinical aspects and recommendations
AI Qureshi, AR Luft, M Sharma, LR Guterman… - …, 2000 - journals.lww.com
We reviewed the incidence, risk factors, and clinical features of thromboembolic and
ischemic events associated with diagnostic cerebral angiography, endovascular treatment of …
ischemic events associated with diagnostic cerebral angiography, endovascular treatment of …
Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
DS Baim, D Wahr, B George, MB Leon, J Greenberg… - Circulation, 2002 - Am Heart Assoc
Background—Stents provide effective treatment for stenotic saphenous venous aorto-
coronary bypass grafts, but their placement carries a 20% incidence of procedure-related …
coronary bypass grafts, but their placement carries a 20% incidence of procedure-related …
[图书][B] Encyclopedia of biomaterials and biomedical engineering
G Wnek, G Bowlin - 2008 - books.google.com
Written by more than 400 subject experts representing diverse academic and applied
domains, this multidisciplinary resource surveys the vanguard of biomaterials and …
domains, this multidisciplinary resource surveys the vanguard of biomaterials and …
Protected carotid stenting: clinical advantages and complications of embolic protection devices in 442 consecutive patients
A Cremonesi, R Manetti, F Setacci, C Setacci… - Stroke, 2003 - Am Heart Assoc
Background and Purpose—Periprocedural embolization of debris during carotid stenting
interventions may result in neurological deficit. This study was designed to evaluate in …
interventions may result in neurological deficit. This study was designed to evaluate in …
Cerebral protection with filter devices during carotid artery stenting
Background—Distal embolization of debris during percutaneous carotid artery stenting may
result in neurological deficit. Filter devices for cerebral protection potentially reduce the risk …
result in neurological deficit. Filter devices for cerebral protection potentially reduce the risk …
Reperfusion injury in humans: a review of clinical trials on reperfusion injury inhibitory strategies
MT Dirksen, GJ Laarman, ML Simoons… - Cardiovascular …, 2007 - academic.oup.com
The principal therapy in patients with myocardial infarction to limit infarct size is myocardial
reperfusion by mechanical or pharmacological intervention. Reperfusion has been …
reperfusion by mechanical or pharmacological intervention. Reperfusion has been …
Cerebral protection during carotid artery stenting: collection and histopathologic analysis of embolized debris
A Angelini, B Reimers, MD Barbera, S Saccà… - Stroke, 2002 - Am Heart Assoc
Background and Purpose—Histopathologic analysis was performed to better understand
quantity, particle size, and composition of embolized debris collected in protection filters …
quantity, particle size, and composition of embolized debris collected in protection filters …
[HTML][HTML] Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis
T Ohki, J Parodi, FJ Veith, M Bates, M Bade… - Journal of vascular …, 2001 - Elsevier
Objective: The role of percutaneous angioplasty and stenting of carotid bifurcation lesions
has been limited by its potential for producing embolic debris. We evaluated the efficacy of a …
has been limited by its potential for producing embolic debris. We evaluated the efficacy of a …
Cerebral ischemia detected with diffusion-weighted MR imaging after stent implantation in the carotid artery
HJ Jaeger, KD Mathias, E Hauth… - American journal …, 2002 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Concern regarding the safety of stent implantation in the
carotid artery exists because of the risk of cerebral embolization during the procedure. The …
carotid artery exists because of the risk of cerebral embolization during the procedure. The …