Uncertainty and sensitivity analyses of energy and visual performances of office building with external venetian blind shading in hot-dry climate

R Singh, IJ Lazarus, VVN Kishore - Applied energy, 2016 - Elsevier
Fenestration has become an integral part of the buildings and has a significant impact on the
energy and indoor visual performances. Inappropriate design of the fenestration component …

Parametric study of venetian blinds for energy performance evaluation and classification in residential buildings

Y Tan, J Peng, Y Luo, J Gao, Z Luo, M Wang… - Energy, 2022 - Elsevier
Venetian blinds are widely used to improve the performance of window systems, while their
energy-saving potentials vary with different materials. This paper aims to undertake a …

Cooling load characteristic and uncertainty analysis of a hub airport terminal

L Lin, X Liu, T Zhang, X Liu, X Rong - Energy and Buildings, 2021 - Elsevier
The airport terminal is a multi-region public transport building with special functions and the
cooling load is a basic parameter determining the air-conditioning system for this special …

Sensitivity analysis and prediction of shading effect of external Venetian blind for nearly zero-energy buildings in China

H Huo, W Xu, A Li, J Chu, Y Lv - Journal of Building Engineering, 2021 - Elsevier
External Venetian blind shading (EVBS) is identified as an effective technology for reducing
cooling demand in summer. Inappropriate design of the fenestration component may led to …

Sensitivity Analysis for Decisive Design Parameters for Energy and Indoor Visual Performances of a Glazed Façade Office Building

R Singh, D Buddhi, S Thapa, C Prakash, R Singh… - Sustainability, 2022 - mdpi.com
The large size of a glazed component allows greater access to natural light inside and a
wider view of the outdoors while protecting the inside from extreme weather conditions …

Erosion Behaviour of Al2O3 Coatings Deposited by Plasma Spray on AISI-316 Substrate

G Prashar, H Vasudev - Advances in Functional and Smart Materials …, 2022 - Springer
The current experimental study focuses on the deposition of Al2O3 ceramic coating on AISI-
316 samples by the plasma spray (PS) technique. Erosive wear test was performed at 30° …

Effect of overhang shade on the solar heat gain through window in composite climatic in Mid-Western India

M Joshi, D Buddhi, R Singh - Journal of Scientific & Industrial …, 2022 - op.niscpr.res.in
Solar heat gain (SHG) through fenestration (window) dominates towards cooling demands
in buildings and eventually increases electricity consumption. Integration of fixed shading …

Effect of Glazing Materials and Shading Position on the Energy Consumption Pattern and Indoor Visual Comfort of Office Building

R Singh, IJ Lazarus, D Buddhi - … in Functional and Smart Materials: Select …, 2022 - Springer
There has been an increase in the use of glazed façades in new buildings, allowing access
to daylight, solar gain, and external view. Hence, a significant attention needs to be devoted …

[PDF][PDF] Sensitivity analysis of influential design parameters for south oriented glazed façade office

R Singh, D Buddhi, A Verma, R Singh, S Sheoran - Energ Proc, 2021 - academia.edu
ABSTRACT Buildings are accountable around 30-40% of global energy consumption. The
modern designs of building with significantly large size of glazed façade are trending and …

[引用][C] The energy performance evaluation of Etfe (Ethylene tetrafluoroethylene) cusion systems integrated on the south façade of a hypothetical test room and …

S Karaman - 2019