Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil
Analysis of real operating condition revealed that HVDC transformers experience combined
effect of DC biased AC electric field. The dynamics of pressboard particle in contaminated …
effect of DC biased AC electric field. The dynamics of pressboard particle in contaminated …
Study on micro bridge impurities in oil-paper insulation at DC voltage: Their generation, growth and interaction with partial discharge
Y Li, Q Zhang, J Li, T Wang, W Dong… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
To investigate the characteristics of micro bridges and their interactions with partial
discharge (PD) in oil-paper insulation under DC voltage, an experimental platform with two …
discharge (PD) in oil-paper insulation under DC voltage, an experimental platform with two …
Experimental studies of influence of different electrodes on bridging in contaminated transformer oil
Contaminated transformer oil has been tested under non uniform electric fields and the
effect of different electrode systems presented in this paper. Three different electric fields …
effect of different electrode systems presented in this paper. Three different electric fields …
Bridging phenomenon in contaminated transformer oil
The effect of cellulose particles contamination on transformer oil has been investigated.
Different sizes and concentration levels of cellulose fibres were used to contaminate the …
Different sizes and concentration levels of cellulose fibres were used to contaminate the …
Bridging in contaminated transformer oil under DC and AC electric field
There are two experimental set up have been established to investigate the bridging effect
between two electrodes with different potentials under ac and dc voltages. This paper will …
between two electrodes with different potentials under ac and dc voltages. This paper will …
Bridging in contaminated transformer oil under AC, DC and DC biased AC electric field
Cellulose particle accumulation under AC, DC and DC biased AC electric field in
transformer oil has been investigated in this paper. Different levels of particle concentrations …
transformer oil has been investigated in this paper. Different levels of particle concentrations …
Pre-breakdown characteristics of contaminated power transformer oil
G Chen, MH Zuber - 2007 Annual Report-Conference on …, 2007 - ieeexplore.ieee.org
In this paper we have studied pre-breakdown characteristics of transformer oil in the
presence of different levels of contamination. The contaminant is fibrous dust from …
presence of different levels of contamination. The contaminant is fibrous dust from …
Influence of contamination on the electrical performance of power transformer oil
S Mahmud - 2015 - eprints.soton.ac.uk
Transformer failure statistics from all over the world showed that almost 30% of them were
due to insulation. Large amount of those failures were due to particles in transformer oil …
due to insulation. Large amount of those failures were due to particles in transformer oil …
Numerical simulations of bridging phenomena in contaminated transformer oil
Experiments were carried out on transformer oil contaminated by cellulose fibre. After the
high voltage was applied to the electrodes, the pressboard particles accumulated in the …
high voltage was applied to the electrodes, the pressboard particles accumulated in the …
Exploratory talk within collaborative small groups in mathematics
JA Edwards, K Jones - Proceedings of the British society for …, 2001 - eprints.soton.ac.uk
This report describes one aspect of a wider research study on exploratory talk within
collaborative small groups in secondary mathematics lessons. It outlines students' views of …
collaborative small groups in secondary mathematics lessons. It outlines students' views of …