A survey on intelligent system application to fault diagnosis in electric power system transmission lines

VH Ferreira, R Zanghi, MZ Fortes, GG Sotelo… - Electric Power Systems …, 2016 - Elsevier
Fault analysis and diagnosis constitute a relevant problem in power systems, with important
economic impacts for operators, maintenance agents and the power industry in general …

Laboratory investigations on factors affecting soil electrical resistivity and the measurement

M Zhou, J Wang, L Cai, Y Fan… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
Soil electrical resistivity is an important parameter in grounding system design. In this paper,
laboratory measurements of soil electrical resistivity are carried out using a soil box. Two …

High frequency response of grounding electrodes: effect of soil dielectric constant

B Salarieh, J De Silva, B Kordi - IET Generation, Transmission …, 2020 - Wiley Online Library
Grounding electrodes have an important role in electric power transmission and distribution
systems. They are used to prevent excessive hazardous voltages due to ground potential …

A study on external electromagnetic characteristics of underground cables with consideration of terminations

H Xue, A Ametani, K Yamamoto - IEEE Transactions on Power …, 2020 - ieeexplore.ieee.org
The characteristics of external electromagnetic fields (EEMFs) produced by underground
cables in the lossy earth are further investigated and studied. This paper develops an …

Influence of frequency characteristics of soil parameters on ground-return transmission line parameters

Z Li, J He, B Zhang, Z Yu - Electric Power Systems Research, 2016 - Elsevier
Electromagnetic transient processes are strongly related to the parameters of transmission
lines. With the ground return parameters considered, the frequency dependent parameters …

Device for the field measurements of frequency-dependent soil properties in the frequency range of lightning currents

D Kuklin - Review of Scientific Instruments, 2020 - pubs.aip.org
Existing approaches for the field measurements of the frequency-dependent soil properties
take a significant amount of time, making it difficult to obtain new experimental data and …

Model and experimental detection of single phase-to-earth faults of overhead conductors in 6–10 kV distribution circuits by a location method

RG Minullin, YV Piskovatskiy… - 2020 International Ural …, 2020 - ieeexplore.ieee.org
The paper considers simulation model of a linear radio-frequency path of overhead power
line implemented in the PSCAD software environment, which allows studying the …

Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents

JH Choi, BH Lee, SK Paek - Journal of Electrical Engineering and …, 2012 - koreascience.kr
When surges and electromagnetic pulses from lightning or power conversion devices are
considered, it is desirable to evaluate grounding system performance as grounding …

Electric fields of grounding electrodes with frequency dependent soil parameters

RS Alipio, MAO Schroeder, MM Afonso… - Electric Power Systems …, 2012 - Elsevier
The profile of the electric field developed at the ground level above a horizontal grounding
electrode due to the impression to the electrode of waves resembling lightning currents of …

Transient impedance of grounding grids with different soil models

E Stracqualursi, R Araneo - 2021 IEEE International …, 2021 - ieeexplore.ieee.org
Transient response of grounding systems to lightning or fault currents is fundamental for
insulation coordination and safety purpose. This work deals with the computation of the …