A comprehensive study of wide-area damping controller requirements through real-time evaluation with operational uncertainties in modern power systems

A Kumar, M Bhadu - IETE Journal of Research, 2023 - Taylor & Francis
In interconnected modern power systems, renewable energy sources, HVDC transmission
lines, and energy storage devices are growing after being installed globally with …

A hybrid particle swarm optimization algorithm for the wide-area damping control design

MEC Bento - IEEE Transactions on Industrial Informatics, 2021 - ieeexplore.ieee.org
The presence of low-frequency and low-dampened oscillation modes can compromise the
operating stability of power systems. Recent research has shown that the use of phasor …

A method based on linear matrix inequalities to design a wide-area damping controller resilient to permanent communication failures

MEC Bento, RA Ramos - IEEE Systems Journal, 2020 - ieeexplore.ieee.org
One of the main advantages of the wide-area measurement systems in the small-signal
stability of the electric power systems is to use synchrophasor data from the phasor …

A wide-area damping controller considering network input and output delays and packet drop

BP Padhy, SC Srivastava… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper presents the development of a novel synchrophasor measurement-based wide-
area centralized damping controller to improve the stability of a power system in presence of …

A dynamic coherency identification method based on frequency deviation signals

AM Khalil, R Iravani - IEEE Transactions on Power Systems, 2015 - ieeexplore.ieee.org
This paper presents a new method to dynamically determine coherent generators and
electrical areas of an interconnected power system. The proposed method is based on …

WAMS-based coherency detection for situational awareness in power systems with renewables

Z Lin, F Wen, Y Ding, Y Xue, S Liu… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
With the ever-increasing penetration level of renewable generation sources, a modern
power system is facing more inevitable uncertainties that could lead to weakly damped …

Taxonomy of coherency detection and coherency‐based methods for generators grouping and power system partitioning

MHR Koochi, S Esmaeili… - IET Generation …, 2019 - Wiley Online Library
In a bulk power system, generators can be divided into groups based on the variation of their
swing curves after disturbance occurrence. In this regard, generators that have the same …

Power system coherency identification under high depth of penetration of wind power

AM Khalil, R Iravani - IEEE Transactions on Power Systems, 2018 - ieeexplore.ieee.org
This paper extends the dynamic coherency determination (DCD) method by including Type-
3 wind power plants (WPPs) models in the coherency evaluation process and quantifies …

Enabling Aggregation of Heterogenous Grid-Forming Inverters via Enclaved Homogenization

MF Umar, M Hosseinzadehtaher, MB Shadmand - IEEE access, 2022 - ieeexplore.ieee.org
This paper proposes a control scheme to force homogeneity for heterogenous network of the
grid-forming (GFM) inverters in power electronics dominated grid (PEDG) to enable their …

A robust decentralized wide area damping controller for wind generators and FACTS controllers considering load model uncertainties

VVG Krishnan, SC Srivastava… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper presents a systematic procedure to design a decentralized wide area damping
controller for the wind farms and flexible ac transmission system (FACTS) controllers in a …