Stator inter turns fault detection using discrete wavelet transform

H Cherif, A Menacer, B Bessam… - 2015 IEEE 10th …, 2015 - ieeexplore.ieee.org
The main objective of this paper presents a discrete wavelet transform (DWT) to diagnoses
the stator inter-turns faults in three induction motor. This technique is based on the analysis …

Inter phase fault detection in inverter fed induction motor using wavelet transform

BA Vinayak, R Uddin… - 2017 3rd International …, 2017 - ieeexplore.ieee.org
In this research an inter-phase fault in the stator winding of Induction Motor will be analyzed
by varying the switching frequency of the sine PWM inverter under different loading …

Open phase fault analysis of a three-phase induction motor

P Singh, RN Dash, CK Panigrahi - Advances in Power Systems and …, 2021 - Springer
The induction machine is a more frequently applied machine in the industry due to its sturdy
nature. Unlike another electrical machine because of the electrical and mechanical strain …

MSCP Based Stator Fault Identification in Induction Motor Using Power Quality Analyzer

WR Babu, M Sundaram, A Kavithamani… - … on Intelligent Data …, 2023 - ieeexplore.ieee.org
Most of the machines are driven by Induction motor nowadays. Induction motor gets failure
due to various reasons. This fault mostly occurs in the stator. By measuring the current of a …

[PDF][PDF] Energy Management by Online Efficiency Estimation and Condition Monitoring of Induction Motor

A Jacob, V Jose, D Sebastian - International Journal of Advanced …, 2014 - researchgate.net
Induction motors are the most commonly used machine in industry because of their robust
nature. Energy management of induction motor is relevant as they form the bulk segment in …

[PDF][PDF] Analysis for inter turn stator fault with load variation in Induction Motor

H Cherif, M Maamir, SE Chehaidia - researchgate.net
This paper investigates the impact of load variation on the diagnosis of inter-turn stator faults
in induction machines. The proposed detection technique relies on the analysis of stator …

International Journal of Energetica Journal/International Journal of Energetica/Vol. 8 No. 1 (2023)/Articles Open Access

This paper investigates the impact of load variation on the diagnosis of inter-turn stator faults
in induction machines. The proposed detection technique relies on the analysis of stator …

Diagnosis of stator inter-turn fault and supply voltage unbalance using phase-angle and magnitude of the line currents spectra

AH BOUDINAR, M KHODJA… - 2018 6th …, 2018 - ieeexplore.ieee.org
This paper describes a new diagnosis approach to discriminate between the supply voltage
unbalance and the stator inter-turn fault in induction motor. This approach is based on a …

Application of Sweep Frequency Response Analysis and Locked-Rotor Test for Stator Winding Inter-Turn and Broken Rotor Bar Fault Detection of Squirrel-Cage …

CJ Boniface - 2021 - open.uct.ac.za
The field of electromagnetic energy conversion has been dominated by induction motors,
where more than 80% are three-phase squirrel-cage induction motors (SCIM)[1],[2]. Despite …

Investigating the effects of unbalanced voltages on Three-phase induction motor performance

D Allison - 2014 - researchportal.murdoch.edu.au
The purpose of this study is to examine and demonstrate the effects that unbalanced supply
voltages have on the operation and performance of a three-phase induction motor. Unlike a …