Update on time-of-flight PET imaging

S Surti - Journal of Nuclear Medicine, 2015 - Soc Nuclear Med
Time-of-flight (TOF) PET was initially introduced in the early days of PET. The TOF PET
scanners developed in the 1980s had limited sensitivity and spatial resolution, were …

Iterative reconstruction techniques in emission computed tomography

J Qi, RM Leahy - Physics in Medicine & Biology, 2006 - iopscience.iop.org
In emission tomography statistically based iterative methods can improve image quality
relative to analytic image reconstruction through more accurate physical and statistical …

Benefit of time-of-flight in PET: experimental and clinical results

JS Karp, S Surti, ME Daube-Witherspoon… - Journal of Nuclear …, 2008 - Soc Nuclear Med
Significant improvements have made it possible to add the technology of time-of-flight (TOF)
to improve PET, particularly for oncology applications. The goals of this work were to …

Advances in time-of-flight PET

S Surti, JS Karp - Physica medica, 2016 - Elsevier
This paper provides a review and an update on time-of-flight PET imaging with a focus on
PET instrumentation, ranging from hardware design to software algorithms. We first present …

Impact of image-space resolution modeling for studies with the high-resolution research tomograph

FC Sureau, AJ Reader, C Comtat, C Leroy… - Journal of Nuclear …, 2008 - Soc Nuclear Med
Brain PET in small structures is challenged by low resolution inducing bias in the activity
measurements. Improved spatial resolution may be obtained by using dedicated …

Overview of methods for image reconstruction from projections in emission computed tomography

RM Lewitt, S Matej - Proceedings of the IEEE, 2003 - ieeexplore.ieee.org
Emission computed tomography (ECT) is a technology for medical imaging whose
importance is increasing rapidly. There is a growing appreciation for the value of the …

One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays

AJ Reader, S Ally, F Bakatselos… - … on Nuclear Science, 2002 - ieeexplore.ieee.org
High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with
high count rate performance, such as the quad-high density avalanche chamber (HIDAC) …

EM algorithm system modeling by image-space techniques for PET reconstruction

AJ Reader, PJ Julyan, H Williams… - … on Nuclear Science, 2003 - ieeexplore.ieee.org
Methodology for PET system modeling using image-space techniques in the expectation
maximization (EM) algorithm is presented. The approach, applicable to both list-mode data …

Iterative reconstruction algorithms in nuclear medicine

S Vandenberghe, Y D'Asseler, R Van de Walle… - … medical imaging and …, 2001 - Elsevier
Iterative reconstruction algorithms produce accurate images without streak artifacts as in
filtered backprojection. They allow improved incorporation of important corrections for image …

Four‐dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction

A Rahmim, J Tang, H Zaidi - Medical physics, 2009 - Wiley Online Library
In this article, the authors review novel techniques in the emerging field of spatiotemporal
four‐dimensional (4D) positron emission tomography (PET) image reconstruction. The …