Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
Small animal radiotherapy research platforms
F Verhaegen, P Granton… - Physics in Medicine & …, 2011 - iopscience.iop.org
Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy
research have recently stimulated the development of precise micro-irradiators for small …
research have recently stimulated the development of precise micro-irradiators for small …
[PDF][PDF] BEAMnrc users manual
DWO Rogers, B Walters, I Kawrakow - Nrc Report Pirs, 2009 - nrc-cnrc.github.io
Abstract BEAMnrc is a Monte Carlo simulation system (Med. Phys. 22, 1995, 503–524) for
modelling radiotherapy sources which was developed as part of the OMEGA project to …
modelling radiotherapy sources which was developed as part of the OMEGA project to …
Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
ON Vassiliev, TA Wareing, J McGhee… - Physics in Medicine …, 2010 - iopscience.iop.org
A new grid-based Boltzmann equation solver, Acuros™, was developed specifically for
performing accurate and rapid radiotherapy dose calculations. In this study we …
performing accurate and rapid radiotherapy dose calculations. In this study we …
Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study
SH Cho - Physics in Medicine & Biology, 2005 - iopscience.iop.org
A recent mice study demonstrated that gold nanoparticles could be safely administered and
used to enhance the tumour dose during radiation therapy. The use of gold nanoparticles …
used to enhance the tumour dose during radiation therapy. The use of gold nanoparticles …
Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
K Bush, IM Gagne, S Zavgorodni, W Ansbacher… - Medical …, 2011 - Wiley Online Library
Purpose: The dosimetric accuracy of the recently released Acuros® XB advanced dose
calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single …
calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single …
The dosimetric feasibility of gold nanoparticle-aided radiation therapy (GNRT) via brachytherapy using low-energy gamma-/x-ray sources
SH Cho, BL Jones, S Krishnan - Physics in Medicine & Biology, 2009 - iopscience.iop.org
The preferential accumulation of gold nanoparticles within tumors and the increased
photoelectric absorption due to the high atomic number of gold cooperatively account for the …
photoelectric absorption due to the high atomic number of gold cooperatively account for the …
FLASH radiotherapy and the use of radiation dosimeters
S Siddique, HE Ruda, JCL Chow - Cancers, 2023 - mdpi.com
Simple Summary FLASH radiotherapy (RT) delivering ultra-high dose rate radiation can
reduce normal tissue toxicity while effectively treating tumors. However, implementing …
reduce normal tissue toxicity while effectively treating tumors. However, implementing …
Metal artifacts in computed tomography for radiation therapy planning: dosimetric effects and impact of metal artifact reduction
A significant and increasing number of patients receiving radiation therapy present with
metal objects close to, or even within, the treatment area, resulting in artifacts in computed …
metal objects close to, or even within, the treatment area, resulting in artifacts in computed …
Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
Monte Carlo (MC) dose calculations are performed on patient geometries derived from
computed tomography (CT) images. For most available MC codes, the Hounsfield units (HU) …
computed tomography (CT) images. For most available MC codes, the Hounsfield units (HU) …