Incidence, cost, complications and clinical outcomes of iatrogenic urethral catheterization injuries: a prospective multi-institutional study

NF Davis, MR Quinlan, NR Bhatt, C Browne… - The Journal of …, 2016 - Elsevier
Purpose Data on urethral catheter related injuries are sparse. To highlight the dangers
inherent in traumatic urethral catheterization we prospectively monitored the incidence, cost …

Long-term outcomes of urethral catheterisation injuries: a prospective multi-institutional study

NF Davis, NR Bhatt, E MacCraith, HD Flood… - World journal of …, 2020 - Springer
Purpose There are no prospective data describing the incidence and spectrum of long-term
complications associated with traumatic urethral catheterisation (UC). We prospectively …

[HTML][HTML] A prospective audit on the effect of training and educational workshops on the incidence of urethral catheterization injuries

NR Bhatt, NF Davis, MR Quinlan, RJ Flynn… - Canadian Urological …, 2017 - ncbi.nlm.nih.gov
Methods A prospective audit was performed to calculate incidence, morbidity, and costs
associated with iatrogenic UC injury from January to July 2015. Educational workshops …

[HTML][HTML] Cryopreservation of porcine urethral tissue: Storage at− 20 C preserves the mechanical, failure and geometrical properties

CV Cunnane, SM Croghan, MT Walsh… - Journal of the …, 2021 - Elsevier
Cryopreservation is required to preserve the native properties of tissue for prolonged
periods of time. In this study, we evaluate the impact that 4 different cryopreservation …

Static and dynamic characteristics of a compound sphere using initial stress reference independence

S Mukherjee, AK Mandal - International Journal of Non-Linear Mechanics, 2021 - Elsevier
We study the influence of residual stress on the static and dynamic characteristics of a
spherical structure. We consider a shrink-fitted compound sphere, where residual stress is …

Clinical evaluation of a safety-device to prevent urinary catheter inflation related injuries

NF Davis, EM Cunnane, ROC Mooney, JC Forde… - Urology, 2018 - Elsevier
Objective To evaluate the feasibility of a novel “safety-valve” device for preventing catheter
related urethral trauma during urethral catheterization (UC). To assess the opinions of …

The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series

V Subramanian, BM Soni, PL Hughes, G Singh… - Patient Safety in …, 2016 - Springer
Background Inflating the balloon of Foley catheter in urethra is a complication of urethral
catheterisation. We report five patients in whom this complication occurred because of …

Evaluating the cost of iatrogenic urethral catheterisation injuries

NR Bhatt, NF Davis, D Addie, R Flynn… - Irish Journal of Medical …, 2017 - Springer
Introduction Technique is vital to prevent urethral trauma during urethral catheterisation
(UC). Education programmes are helpful but are not compulsory and safe UC remains …

Possible Use of a Safety-Valve with a Foley Catheter During Catheterisation of Male Spinal Cord Injury Patients for Prevention of Urethral Trauma Caused by Inflation …

V Subramanian, BM Soni - Medical Devices: Evidence and …, 2023 - Taylor & Francis
We used a safety-valve (Trans-Urethral Catheterisation Safety Valve, Class Medical,
Limerick, Ireland) to prevent urethral trauma due to inflation of the anchoring balloon in the …

Cost-effectiveness of a novel urethral catheter safety device in preventing catheterization injuries in the UK

SM Croghan, R Malcolm, HD Flood… - Journal of Medical …, 2024 - Taylor & Francis
Aims Intraurethral catheter balloon inflation is a substantial contributor to significant catheter-
related urethral injury. A novel safety valve has been designed to prevent these balloon …