Novel programmable readout amplifier and potentiostat for glucose sensing applications
The paper presents a novel design of programmable current mode readout amplifier and
potentiostat circuits for glucose sensing applications. In the proposed design, the threshold …
potentiostat circuits for glucose sensing applications. In the proposed design, the threshold …
Novel tunable current feedback instrumentation amplifier based on BBFC OP-AMP for biomedical applications with low power and high CMRR
The paper presents a novel low power, low noise and high CMRR current feedback
instrumentation amplifier (CFIA) design for biomedical signal acquisition ie EEG/ECG …
instrumentation amplifier (CFIA) design for biomedical signal acquisition ie EEG/ECG …
A low-noise and mismatch-tolerant current-mirror-based potentiostat circuit for glucose monitoring
K Nam, G Choi, M Yoo, S Kang, B Jin, H Son… - Microelectronics …, 2023 - Elsevier
Potentiostat circuits are widely used to monitor biochemical signals such as glucose and
viruses. Here, we proposed a potentiostat circuit that is an amperometric sensor with a three …
viruses. Here, we proposed a potentiostat circuit that is an amperometric sensor with a three …
Programmable Readout with Integrated Bandgap Reference Potentiostat for Glucose Sensing
A novel electronics interface which includes programmable readout amplifier and bandgap
reference voltage potentiostat circuit for glucose electrochemical sensors is designed and …
reference voltage potentiostat circuit for glucose electrochemical sensors is designed and …
Dielectric-modulated double gate bilayer electrode organic thin film transistor-based biosensor for label-free detection: simulation study and sensitivity analysis
A dielectric-modulated double gate bilayer electrodes organic thin-film transistor (DMDGBE-
OTFT) based sensor is proposed for label-free biomolecule detection. The double gate of …
OTFT) based sensor is proposed for label-free biomolecule detection. The double gate of …
Programmable transimpedance amplifier with integrated bandgap reference for glucose concentration measurement
For glucose electrochemical sensors, a comprehensive electronics interface is designed
and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This …
and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This …
A signal conditioning circuit with integrated bandgap reference for glucose concentration measurement
The paper presents development of signal conditioning circuit with integrated potentiostat for
glucose measurement. The programmable transimpedance amplifier (PTIA) offers 94 …
glucose measurement. The programmable transimpedance amplifier (PTIA) offers 94 …
A Low- Power Low-Noise Current-Feedback Instrumentation Amplifier based on gm boosted OTA for ECG Acquisition
This paper presents a CMOS operational transconductance amplifier (OTA) based current-
feedback instrumentation amplifier (CFIA) optimized for low-power and low-noise …
feedback instrumentation amplifier (CFIA) optimized for low-power and low-noise …
[HTML][HTML] Low-Noise Potentiostat Readout Circuit with a Chopper Fully Differential Difference Amplifier for Glucose Monitoring
G Choi, K Nam, M Yoo, S Kang, B Jin, K Kim, H Son… - Applied Sciences, 2022 - mdpi.com
This paper presents a low-noise potentiostat readout circuit with a chopper fully differential
difference amplifier (FDDA) for glucose monitoring. Glucose monitoring is necessary for the …
difference amplifier (FDDA) for glucose monitoring. Glucose monitoring is necessary for the …