[图书][B] Handbook of anatomical models for radiation dosimetry

XG Xu, KF Eckerman - 2009 - books.google.com
This pioneering work brings together recommendations sanctioned by the International
Commission on Radiological Protection (ICRP) and documents 40 years of cutting-edge …

Characterizing anatomical variability in breast CT images

KG Metheany, CK Abbey, N Packard… - Medical …, 2008 - Wiley Online Library
Previous work [Burgess et al., Med. Phys. 28, 419–437 (2001)] has shown that anatomical
noise in projection mammography results in a power spectrum well modeled over a range of …

Does image quality matter? Impact of resolution and noise on mammographic task performance

RS Saunders Jr, JA Baker, DM Delong… - Medical …, 2007 - Wiley Online Library
The purpose of this study was to examine the effects of different resolution and noise levels
on task performance in digital mammography. This study created an image set with images …

To bin or not to bin? The effect of CT system limiting resolution on noise and detectability

J Baek, AR Pineda, NJ Pelc - Physics in Medicine & Biology, 2013 - iopscience.iop.org
We examine the noise advantages of having a computed tomography (CT) detector whose
spatial resolution is significantly better (eg a factor of 2) than needed for a desired resolution …

Beyond noise power in 3D computed tomography: the local NPS and off‐diagonal elements of the Fourier domain covariance matrix

AR Pineda, DJ Tward, A Gonzalez… - Medical …, 2012 - Wiley Online Library
Purpose: To investigate the correlation and stationarity of noise in volumetric computed
tomography (CT) using the local discrete noise‐power spectrum (NPS) and off‐diagonal …

Evaluating the impact of x‐ray spectral shape on image quality in flat‐panel CT breast imaging

SJ Glick, S Thacker, X Gong, B Liu - Medical Physics, 2007 - Wiley Online Library
In recent years, there has been an increasing interest in exploring the feasibility of dedicated
computed tomography (CT) breast imaging using a flat‐panel digital detector in a truncated …

Effect of noise on MTF calculations using different phantoms

A González‐López - Medical Physics, 2018 - Wiley Online Library
Purpose In this work, the effect of noise on the precision in the modulation transfer function
(MTF) calculation using different phantoms is investigated. Three different techniques are …

Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems

CP Favazza, KA Fetterly… - Journal of Medical …, 2015 - spiedigitallibrary.org
Evaluation of flat-panel angiography equipment through conventional image quality metrics
is limited by the scope of standard spatial-domain image quality metric (s), such as contrast …

Amorphous selenium flat panel detectors for digital mammography: validation of a NPWE model observer with CDMAM observer performance experiments

JA Segui, W Zhao - Medical Physics, 2006 - Wiley Online Library
Model observers have been developed which incorporate a specific imaging task, system
performance, and human observer characteristics and can potentially overcome some of the …

Signal detection and location‐dependent noise in cone‐beam computed tomography using the spatial definition of the Hotelling SNR

CC Brunner, SF Abboud, C Hoeschen… - Medical …, 2012 - Wiley Online Library
Purpose: Quality assurance in computed tomography (CT) is commonly performed with the
Fourier‐based modulation transfer function (MTF) and the noise variance, while more …