A review on protection of capacitor in power quality industry
LV Teli, HT Jadhav - 2018 International Conference on Current …, 2018 - ieeexplore.ieee.org
In large industry, power factor has become a majorissue in power system. Many industries
have been using a capacitor bank for power factor improvement and reactive power …
have been using a capacitor bank for power factor improvement and reactive power …
[PDF][PDF] Numerical research of operation circuit breakers with pre-insertion resistors at switching power capacitor banks
The article presents results of numerical research of switching (energization and de-
energization) power capacitor banks equipped by special switchers which include the sets …
energization) power capacitor banks equipped by special switchers which include the sets …
Some features of capacitor banks automatic switching-offs computer simulation
T Lazimov, R Ahmadov - IFAC-PapersOnLine, 2018 - Elsevier
Switching-off high-voltage power capacitor banks is one of the most unfavorable transitional
processes for the equipment of power electric systems from the point of view dangerous …
processes for the equipment of power electric systems from the point of view dangerous …
Inrush current investigation of capacitor bank switching for 150kV electrical system in Indonesia
PAA Pramana, AA Kusuma… - … Conference on High …, 2017 - ieeexplore.ieee.org
Circuit breaker (CB) installed for capacitor bank is the CB which commonly experiences the
switching process due to the capacitor bank function as a voltage regulator. In closing …
switching process due to the capacitor bank function as a voltage regulator. In closing …
[HTML][HTML] Analysis of mechanical damage characteristics of closing resistor of 800kV tank circuit breaker with multi-physical field
Y Bao, K Liu, F Wang - Journal of Measurements in Engineering, 2024 - extrica.com
The closing resistor sheet in the 800 kV tank circuit breaker, used in Northwest China, has
been repeatedly damaged due to internal stress concentration during the opening and …
been repeatedly damaged due to internal stress concentration during the opening and …
Method for Determining the Resonant Frequencies of Extra High Voltage Power Transmission Line
M Belik, V Kuchanskyy… - … Elektrotechniczny.№ 10: 39 …, 2023 - ir.lib.vntu.edu.ua
The paper proposes a mathematical model for determining the resonant frequency of a 750
kV line relative to an unloaded transformer and studies the possibility of overvoltages in 750 …
kV line relative to an unloaded transformer and studies the possibility of overvoltages in 750 …
A new switching control approach to reduce capacitor bank inrush current
AH Fajariawan, A Aripriharta, I Fadlika… - AIP Conference …, 2020 - pubs.aip.org
This paper presents the results analysis of switching's effect when capacitor bank operation
against the amount of inrush current on the circuit breaker. The capacitor bank switching …
against the amount of inrush current on the circuit breaker. The capacitor bank switching …
Improving Adequacy of Simulation Transitional Processes in Electric Systems by More Comprehensive Consideration Phenomena in Circuit-Breakers
T Lazimov, EAA Saafan, R Ahmadov… - 2019 Modern Electric …, 2019 - ieeexplore.ieee.org
Computer simulation is the main tool for studying transitional processes in electric power
systems including switching transitions of high-voltage system's equipment such as …
systems including switching transitions of high-voltage system's equipment such as …
Study of Anomalous Breakage of Closing Resistors of Circuit Breakers for 750 kV AC Filter Fields
H Wang, H Zhang, H Jin, H Wang, Y Li, Z Ma - Annual Conference of China …, 2023 - Springer
Closing resistors are mainly used in line circuit breakers of 800 kV and above and AC filter
circuit breakers of 550 kV and above to suppress the closing inrush current and transient …
circuit breakers of 550 kV and above to suppress the closing inrush current and transient …
Hao Wang, Hongliang Zhang, Hai Jin, Hong Wang, Yifan Li, and Zhiyin Ma College of Electrical and Information Engineering, Lanzhou University of Technology …
F Fields - The Proceedings of the 18th Annual Conference of …, 2024 - books.google.com
Closing resistors are mainly used in line circuit breakers of 800 kV and above and AC filter
circuit breakers of 550 kV and above to suppress the closing inrush current and transient …