Hemolysis testing in vitro: A review of challenges and potential improvements
K von Petersdorff-Campen, MS Daners - ASAIO journal, 2022 - journals.lww.com
Many medical devices such as cardiopulmonary bypass systems, mechanical heart valves,
or ventricular assist devices are intended to come into contact with blood flow during use. In …
or ventricular assist devices are intended to come into contact with blood flow during use. In …
Acquired platelet defects are responsible for nonsurgical bleeding in left ventricular assist device recipients
Background Left ventricular assist devices (LVADs) have been used as a standard treatment
option for patients with advanced heart failure. However, these devices are prone to adverse …
option for patients with advanced heart failure. However, these devices are prone to adverse …
Extracorporeal membrane oxygenation-induced hemolysis: An in vitro study to appraise causative factors
In vitro hemolysis testing is commonly used to determine hemocompatibility of
ExtraCorporeal Membrane Oxygenation (ECMO). However, poor reproducibility remains a …
ExtraCorporeal Membrane Oxygenation (ECMO). However, poor reproducibility remains a …
In vitro hemocompatibility evaluation of the HeartWare ventricular assist device under systemic, pediatric and pulmonary support conditions
CHH Chan, KK Ki, IY Chu, J Rolls, S Morris… - ASAIO …, 2021 - journals.lww.com
The development of adult use right ventricular assist devices (RVADs) and pediatric left
ventricular assist devices (pediatric LVADs) have significantly lagged behind compared to …
ventricular assist devices (pediatric LVADs) have significantly lagged behind compared to …
The porcine abattoir blood model—Evaluation of platelet function for in‐vitro hemocompatibility investigations
JC Clauser, J Maas, I Mager, FR Halfwerk… - Artificial …, 2022 - Wiley Online Library
Background The major obstacle of blood‐contacting medical devices is insufficient
hemocompatibility, particularly thrombogenicity and platelet activation. Pre‐clinical in‐vitro …
hemocompatibility, particularly thrombogenicity and platelet activation. Pre‐clinical in‐vitro …
Developing Rheological Characterization Methods for Bovine Blood and Hydrogel-Based Artificial Blood
G Hentschel, S Küspert, L de Souza, F Pape… - Annual Transactions of …, 2024 - websok.uis.no
Graphical abstract: Rheological understanding of blood is relevant for the design of
cardiovascular medical devices and implants. Erythrocytes are represented by hydrogel …
cardiovascular medical devices and implants. Erythrocytes are represented by hydrogel …
Acquired Platelet And Neutrophil Dysfunction Due To High Mechanical Shear Stress
K Arias - 2022 - search.proquest.com
Heart failure (HF) is a public health burden. In the next ten years, 8 million Americans are
expected to have HF. A subset of these patients will develop advanced HF. They are …
expected to have HF. A subset of these patients will develop advanced HF. They are …
[PDF][PDF] In vitro Hemocompatibility Evaluation of the HeartWare Ventricular Assist Device Under Systemic, Pediatric and Pulmonary Support Conditions
S BINDORFER, JOP PAULS, IKI IDACHI, JF FRASER - 2020 - researchgate.net
The development of adult use right ventricular assist devices (RVADs) and pediatric left
ventricular assist devices (pediatric LVADs) have significantly lagged behind compared to …
ventricular assist devices (pediatric LVADs) have significantly lagged behind compared to …
Development of a Blood Shear Stress Device using Numerical and Experimental methods
S Karnik - 2020 - search.proquest.com
Abstract Left Ventricular Assist Devices (LVADs) are mechanical pumps used to treat heart
failure, which is the cause of 6.2 million deaths in the United States every year. Despite …
failure, which is the cause of 6.2 million deaths in the United States every year. Despite …