Coronary artery bypass conduits: review of current status.
MJ Reardon, LD Conklin, PR Reardon… - The Journal of …, 1997 - europepmc.org
Coronary artery bypass grafting (CABG) is the most common procedure performed in adult
cardiovascular surgery today. In our Department of Surgery at Baylor College of Medicine …
cardiovascular surgery today. In our Department of Surgery at Baylor College of Medicine …
[HTML][HTML] In vitro comparison of aortic valve movement after valve-preserving aortic replacement
R Fries, T Graeter, D Aicher, H Reul, C Schmitz… - The Journal of Thoracic …, 2006 - Elsevier
OBJECTIVE: In aortic valve regurgitation and aortic dilatation, preservation of the aortic
valve is possible by means of root remodeling (Yacoub procedure) or valve reimplantation …
valve is possible by means of root remodeling (Yacoub procedure) or valve reimplantation …
Turbulence characteristics downstream of bileaflet aortic valve prostheses
JS Liu, PC Lu, SH Chu - J. Biomech. Eng., 2000 - asmedigitalcollection.asme.org
This study was focused on a series of in vitro tests on the turbulent flow characteristics of
three bileaflet aortic valves: St. Jude Medical (SJM), CarboMedics (CM), and Edwards Tekna …
three bileaflet aortic valves: St. Jude Medical (SJM), CarboMedics (CM), and Edwards Tekna …
In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses
M Kuetting, A Sedaghat, M Utzenrath, JM Sinning… - Journal of …, 2014 - Elsevier
Background Although CT-studies as well as intraoperative analyses have described broad
anatomic variations of the aortic annulus, which is predominantly found non-circular …
anatomic variations of the aortic annulus, which is predominantly found non-circular …
Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow
Vascular access methods, performed by the insertion of cannulae into vessels, may disturb
the physiological flow of blood, giving rise to non-physiological pressure variations and …
the physiological flow of blood, giving rise to non-physiological pressure variations and …
Comparative Long-Term Clinical Performance of Mechanical Aortic Valve Prostheses
MG Koski, N Glaser, A Franco-Cereceda… - JAMA Network …, 2024 - jamanetwork.com
Importance Aggregated data and long-term follow-up in national health data registers offer
the opportunity to compare the performance of mechanical aortic prostheses within the same …
the opportunity to compare the performance of mechanical aortic prostheses within the same …
The influence of the leaflets' curvature on the flow field in two bileaflet prosthetic heart valves
M Grigioni, C Daniele, G D'Avenio, V Barbaro - Journal of Biomechanics, 2001 - Elsevier
A successful mechanical prosthetic heart valve design is the bileaflet valve, which has been
implanted for the first time more than 20 years ago. A key feature of bileaflet valves is the …
implanted for the first time more than 20 years ago. A key feature of bileaflet valves is the …
Time-resolved DPIV analysis of vortex dynamics in a left ventricular model through bileaflet mechanical and porcine heart valve prostheses
O Pierrakos, PP Vlachos… - J. Biomech …, 2004 - asmedigitalcollection.asme.org
The performance of the heart after a mitral valve replacement operation greatly depends on
the flow character downstream of the valve. The design and implanting orientation of valves …
the flow character downstream of the valve. The design and implanting orientation of valves …
A prospective controlled trial of St. Jude versus Starr Edwards aortic and mitral valve prostheses
AJ Murday, A Hochstitzky, J Mansfield, J Miles… - The Annals of thoracic …, 2003 - Elsevier
BACKGROUND: There is a paucity of controlled trials comparing the merits of different heart
valve prostheses. In this prospective randomized trial we compared Starr Edwards and St …
valve prostheses. In this prospective randomized trial we compared Starr Edwards and St …
Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prostheses
G Ismeno, A Renzulli, A Carozza, M De Feo… - International journal of …, 1999 - Elsevier
Heart valve replacement with mechanical prosthesis is associated with mild intravascular
hemolysis. In this study we evaluated the incidence of hemolysis in patients with different …