[HTML][HTML] Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations

ED Chan, MM Chan, MM Chan - Respiratory medicine, 2013 - Elsevier
Pulse oximetry has revolutionized the ability to monitor oxygenation in a continuous,
accurate, and non-invasive fashion. Despite its ubiquitous use, it is our impression and …

Pulse oximetry

A Jubran - Critical care, 1999 - Springer
Pulse oximetry is one of the most commonly employed monitoringmodalities in the critical
care setting. This review describes the latesttechnological advances in the field of pulse …

Pulse oximetry in pediatric practice

S Fouzas, KN Priftis, MB Anthracopoulos - Pediatrics, 2011 - publications.aap.org
The introduction of pulse oximetry in clinical practice has allowed for simple, noninvasive,
and reasonably accurate estimation of arterial oxygen saturation. Pulse oximetry is routinely …

Neonatal wearable device for colorimetry-based real-time detection of jaundice with simultaneous sensing of vitals

G Inamori, U Kamoto, F Nakamura, Y Isoda… - Science …, 2021 - science.org
Neonatal jaundice occurs in> 80% of newborns in the first week of life owing to physiological
hyperbilirubinemia. Severe hyperbilirubinemia could cause brain damage owing to its …

Accuracy of pulse oximeters in measuring oxygen saturation in patients with poor peripheral perfusion: a systematic review

K Poorzargar, C Pham, J Ariaratnam, K Lee… - Journal of clinical …, 2022 - Springer
One of the most significant limitations of oximeters is their performance under poor perfusion
conditions. This systematic review examines pulse oximeter model accuracy in adults under …

Toward accurate extraction of respiratory frequency from the photoplethysmogram: Effect of measurement site

V Hartmann, H Liu, F Chen, W Hong, S Hughes… - Frontiers in …, 2019 - frontiersin.org
Background: It is known that the respiration-modulated photoplethysmographic (PPG)
signals could be used to derive respiratory frequency (RF) and that PPG signals could be …

Prevention of perioperative hypothermia in plastic surgery

VL Young, ME Watson - Aesthetic Surgery Journal, 2006 - academic.oup.com
While inadvertent perioperative hypothermia has received serious attention in many surgical
specialties, few discussions of hypothermia have been published in the plastic surgery …

Forehead pulse oximetry: Headband use helps alleviate false low readings likely related to venous pulsation artifact

GS Agashe, J Coakley… - The Journal of the …, 2006 - pubs.asahq.org
Background This study investigated whether a tensioning headband that applies up to 20
mmHg pressure over a forehead pulse oximetry sensor could improve arterial hemoglobin …

Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion

L Schallom, C Sona, M McSweeney, J Mazuski - Heart & Lung, 2007 - Elsevier
OBJECTIVE: Measurement of pulse oximetry (Spo2) is often impaired in critically ill patients.
Forehead reflectance oximetry, the Max-Fast (Nellcor, Pleasanton, CA), may be less …

Evaluation of a new pulse oximeter sensor

M Fernandez, K Burns, B Calhoun, S George… - American Journal of …, 2007 - AACN
• Background A new forehead noninvasive oxygen saturation sensor may improve signal
quality in patients with low cardiac index.• Objectives To examine agreement between …