[PDF][PDF] Solid insulation in DC gas-insulated systems
R Gremaud, F Molitor, C Doiron, T Christen… - Cigré …, 2014 - researchgate.net
The increasing demand for high voltage direct current (HVDC) technology requires the
adaptation of gas insulated switchgear (GIS) or lines (GIL), which were originally developed …
adaptation of gas insulated switchgear (GIS) or lines (GIL), which were originally developed …
[PDF][PDF] Hybrid resistive-capacitive and ion drift model for solid gas dielectrics
N Lavesson, CB Doiron - COMSOL conference 2015, 2015 - comsol.fr
Many electrical insulation systems use a combination of gaseous and solid dielectrics. This
article describes a model, implemented in COMSOL Multiphysics, for simulating the electric …
article describes a model, implemented in COMSOL Multiphysics, for simulating the electric …
DC field distribution around an HVDC cable termination
B Källstrand, D Borg, L Walfridsson… - … IEEE Conference on …, 2015 - ieeexplore.ieee.org
DC field measurements of the electric field around a cable termination have been
performed. The field variation along the surface as well as its time development after voltage …
performed. The field variation along the surface as well as its time development after voltage …
[PDF][PDF] Role and impact of different charge sources on surface charge accumulation in gas insulated HVDC systems
M Schueller - 2014 - research-collection.ethz.ch
Within the framework of this thesis an experimental setup for measuring surface potentials
that are due to accumulated surface charges on gas insulated HVDC model insulators is …
that are due to accumulated surface charges on gas insulated HVDC model insulators is …
[PDF][PDF] Time constant evaluation of transient AC− DC field distribution
This paper focuses on the time constant of transient AC–DC field distribution of DC GIS. As
the resistive field depends on the conductivity of solid and gas surrounding in the GIS, these …
the resistive field depends on the conductivity of solid and gas surrounding in the GIS, these …
Optimum damping resistance of potential transformers for mitigating ferro-resonance in gas insulated substations
M Rayati, AM Ranjbar - International Journal of Electrical Power & Energy …, 2018 - Elsevier
Different methods are developed for mitigation of ferro-resonance in high-voltage gas
insulated substations (GISs). The main components, which have impacts on probability of …
insulated substations (GISs). The main components, which have impacts on probability of …
[PDF][PDF] SCD1 Colloquium
R GREMAUD, M SCHUELLER, CB DOIRON… - researchgate.net
Dimensioning of HVDC GIS requires the knowledge of electric field distributions occurring in
the case of DC application. Starting from a capacitive field distribution at the moment of …