Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Review of fast Monte Carlo codes for dose calculation in radiation therapy treatment planning

K Jabbari - Journal of Medical Signals & Sensors, 2011 - journals.lww.com
An important requirement in radiation therapy is a fast and accurate treatment planning
system. This system, using computed tomography (CT) data, direction, and characteristics of …

BEAM: a Monte Carlo code to simulate radiotherapy treatment units

DWO Rogers, BA Faddegon, GX Ding, CM Ma… - Medical …, 1995 - Wiley Online Library
This paper describes BEAM, a general purpose Monte Carlo code to simulate the radiation
beams from radiotherapy units including high‐energy electron and photon beams, 60Co …

AAPM medical physics practice guideline 5. a.: commissioning and QA of treatment planning dose calculations—megavoltage photon and electron beams

JB Smilowitz, IJ Das, V Feygelman… - Journal of applied …, 2015 - Wiley Online Library
The American Association of Physicists in Medicine (AAPM) is a nonprofit professional
society whose primary purposes are to advance the science, education and professional …

Commissioning and quality assurance of treatment planning computers

J Van Dyk, RB Barnett, JE Cygler… - International Journal of …, 1993 - Elsevier
The process of radiation therapy is complex and involves many steps. At each step,
comprehensive quality assurance procedures are required to ensure the safe and accurate …

DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations

J Sempau, SJ Wilderman… - Physics in Medicine & …, 2000 - iopscience.iop.org
Abstract A new Monte Carlo (MC) algorithm, thedose planning method'(DPM), and its
associated computer program for simulating the transport of electrons and photons in …

Clinical implementation of a Monte Carlo treatment planning system

CM Ma, E Mok, A Kapur, T Pawlicki, D Findley… - Medical …, 1999 - Wiley Online Library
The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy
dose calculations. We used the EGS4/BEAM code to obtain the phase‐space data for 6–20 …

A comparison of dosimetry techniques in stereotactic radiosurgery

M Heydarian, PW Hoban… - Physics in Medicine & …, 1996 - iopscience.iop.org
Accurate dosimetry of small-field photon beams used in stereotactic radiosurgery (SRS) can
be made difficult because of the presence of lateral electronic disequilibrium and steep dose …

MMC-a high-performance Monte Carlo code for electron beam treatment planning

H Neuenschwander, TR Mackie… - Physics in Medicine & …, 1995 - iopscience.iop.org
Abstract The macro Monte Carlo (MMC) method has been developed to improve the speed
of traditional Monte Carlo (MC) high-energy electron transport calculations without loss in …

Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25

BJ Gerbi, JA Antolak, FC Deibel, DS Followill… - Medical …, 2009 - Wiley Online Library
The goal of Task Group 25 (TG‐25) of the Radiation Therapy Committee of the American
Association of Physicists in Medicine (AAPM) was to provide a methodology and set of …