A review of 3D/2D registration methods for image-guided interventions

P Markelj, D Tomaževič, B Likar, F Pernuš - Medical image analysis, 2012 - Elsevier
Registration of pre-and intra-interventional data is one of the key technologies for image-
guided radiation therapy, radiosurgery, minimally invasive surgery, endoscopy, and …

Review of 2-D/3-D reconstruction using statistical shape and intensity models and X-ray image synthesis: Toward a unified framework

CJF Reyneke, M Lüthi, V Burdin… - IEEE reviews in …, 2018 - ieeexplore.ieee.org
Patient-specific three-dimensional (3-D) bone models are useful for a number of clinical
applications such as surgery planning, postoperative evaluation, as well as implant and …

Robust gradient-based 3-D/2-D registration of CT and MR to X-ray images

P Markelj, D Tomazevic, F Pernus… - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
One of the most important technical challenges in image-guided intervention is to obtain a
precise transformation between the intrainterventional patient's anatomy and corresponding …

Evaluation of similarity measures for use in the intensity‐based rigid 2D‐3D registration for patient positioning in radiotherapy

J Wu, M Kim, J Peters, H Chung, SS Samant - Medical physics, 2009 - Wiley Online Library
Purpose: Rigid 2D‐3D registration is an alternative to 3D‐3D registration for cases where
largely bony anatomy can be used for patient positioning in external beam radiation therapy …

Rigid 2D/3D slice‐to‐volume registration and its application on fluoroscopic CT images

W Birkfellner, M Figl, J Kettenbach, J Hummel… - Medical …, 2007 - Wiley Online Library
Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance
imaging to three dimensional (3D) volumes is a special aspect of the two‐dimensional …

Validation for 2D/3D registration I: A new gold standard data set

SA Pawiro, P Markelj, F Pernuš, C Gendrin… - Medical …, 2011 - Wiley Online Library
Purpose: In this article, the authors propose a new gold standard data set for the validation
of two‐dimensional/three‐dimensional (2D/3D) and 3D/3D image registration algorithms …

A digitally reconstructed radiograph algorithm calculated from first principles

D Staub, MJ Murphy - Medical physics, 2013 - Wiley Online Library
Purpose: To develop an algorithm for computing realistic digitally reconstructed radiographs
(DRRs) that match real cone‐beam CT (CBCT) projections with no artificial adjustments …

Registration of 2D C‐arm and 3D CT images for a C‐arm image‐assisted navigation system for spinal surgery

CJ Chang, GL Lin, A Tse, HY Chu… - Applied bionics and …, 2015 - Wiley Online Library
C‐Arm image‐assisted surgical navigation system has been broadly applied to spinal
surgery. However, accurate path planning on the C‐Arm AP‐view image is difficult. This …

Comparison of automatic image registration uncertainty for three IGRT systems using a male pelvis phantom

J Barber, JR Sykes, L Holloway… - Journal of applied …, 2016 - Wiley Online Library
A series of phantom images using the CIRS Virtual Human Male Pelvis was acquired across
available dose ranges for three image‐guided radiotherapy (IGRT) imaging systems: Elekta …

Automatic point correspondence using an artificial immune system optimization technique for medical image registration

KK Delibasis, PA Asvestas, GK Matsopoulos - … medical imaging and …, 2011 - Elsevier
In this paper, an automatic method for determining pairs of corresponding points between
medical images is proposed. The method is based on the implementation of an artificial …