Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians

P Lochner, M Czosnyka, A Naldi, E Lyros, P Pelosi… - Neurological …, 2019 - Springer
Background Estimation of intracranial pressure (ICP) may be helpful in the management of
neurological critically ill patients. It has been shown that ultrasonography of the optic nerve …

Optic nerve sheath diameter assessment by neurosonology: a review of methodologic discrepancies

RRF Stevens, ED Gommer, MJH Aries… - Journal of …, 2021 - Wiley Online Library
Abstract Background and Purpose Reported cutoff values of the optic nerve sheath diameter
(ONSD) for the diagnosis of elevated intracranial pressure (ICP) are inconsistent. This …

Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers

DH Kim, JS Jun, R Kim - Scientific reports, 2017 - nature.com
The optic nerve sheath diameter (ONSD) is considered as an indirect marker for intracranial
pressure (ICP). However, the optimal cut-off value for an abnormal ONSD indicating …

Quantification of optic nerve and sheath diameter by transorbital sonography: a systematic review and metanalysis

C Schroeder, AH Katsanos, D Richter… - Journal of …, 2020 - Wiley Online Library
ABSTRACT BACKGROUND AND PURPOSE To date, normal values for optic nerve
diameter (OND) and optic nerve sheath diameter (ONSD) for transorbital sonography (TOS) …

A proposal for a new protocol for sonographic assessment of the optic nerve sheath diameter: the CLOSED protocol

R Aspide, G Bertolini, L Albini Riccioli, D Mazzatenta… - Neurocritical Care, 2020 - Springer
Measuring and monitoring of intracranial pressure is considered standard of care in patients
with suspected intracranial hypertension. Sonographic assessment of the optic nerve sheath …

Feasibility and usefulness of ultrasonography in idiopathic intracranial hypertension or secondary intracranial hypertension

P Lochner, F Brigo, ML Zedde, S Sanguigni, L Coppo… - BMC neurology, 2016 - Springer
Background Transorbital sonography (TOS) has been proven to be able to non-invasively
detect elevated intracranial pressure. In this condition TOS shows an increase in optic nerve …

B-mode transorbital ultrasonography for the diagnosis of idiopathic intracranial hypertension: a systematic review and meta-analysis

P Lochner, K Fassbender, S Knodel… - Ultraschall in der …, 2019 - thieme-connect.com
In patients with idiopathic intracranial hypertension (IIH), transorbital sonography (TOS) may
reveal an enlargement of the optic nerve sheath diameter (ONSD) and the presence of optic …

Effects of age and sex on optic nerve sheath diameter in healthy volunteers and patients with traumatic brain injury

D Cardim, M Czosnyka, K Chandrapatham… - Frontiers in …, 2020 - frontiersin.org
The measurement of optic nerve sheath diameter (ONSD) has been reported as a non-
invasive marker for intracranial pressure (ICP). Nevertheless, it is uncertain whether …

Effects of sevoflurane and propofol on the optic nerve sheath diameter in patients undergoing laparoscopic gynecological surgery: a randomized controlled clinical …

W Geng, C Chen, X Sun, S Huang - BMC anesthesiology, 2021 - Springer
Background The results of studies on changes in intracranial pressure in patients
undergoing laparoscopic surgery are inconsistent. Meanwhile, previous neurosurgery …

Transorbital sonography: A non-invasive bedside screening tool for detection of pseudotumor cerebri syndrome

JJ Korsbæk, SM Hagen, HW Schytz… - …, 2022 - journals.sagepub.com
Background Our objective was to assess optic nerve sheath diameter (a marker of elevated
intracranial pressure) and optic disc elevation (a marker of papilledema) in pseudotumor …