Microfabricated transition-edge X-ray detectors

GC Hilton, JM Martinis, KD Irwin… - IEEE Transactions …, 2001 - ieeexplore.ieee.org
We are developing high performance X-ray detectors based on superconducting transition-
edge sensors (TES) for application in materials analysis and astronomy. Using our recently …

[HTML][HTML] Thermal fluctuation noise in Mo/Au superconducting transition-edge sensor microcalorimeters

NA Wakeham, JS Adams, SR Bandler… - Journal of Applied …, 2019 - pubs.aip.org
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured
electrical noise exceeds theoretical estimates based on a thermal model of a single body …

Thermal fluctuation noise in a voltage biased superconducting transition edge thermometer

HFC Hoevers, AC Bento, MP Bruijn, L Gottardi… - Applied Physics …, 2000 - pubs.aip.org
The current noise at the output of a microcalorimeter with a voltage biased superconducting
transition edge thermometer is studied in detail. In addition to the two well-known noise …

High-frequency noise peaks in mo/au superconducting transition-edge sensor microcalorimeters

NA Wakeham, JS Adams, SR Bandler… - Journal of Low …, 2020 - Springer
The measured noise in Mo/Au transition-edge sensor (TES) microcalorimeters produced at
NASA has recently been shown to be well described by a two-body electro-thermal model …

Cryogenic imaging spectrometers for X-ray astronomy

PAJ de Korte - Nuclear Instruments and Methods in Physics Research …, 2000 - Elsevier
During 1999 and 2000 three X-ray astronomy satellite missions will be launched. One of
those, the Japanese ASTRO-E, carries the first cryogenic X-ray imaging spectrometer with …

Fabrication and characterization of Al-Mn superconducting films for applications in TES bolometers

Q Yu, YF Zhang, CH Zhao, KY He, RT Huang… - Chinese …, 2021 - iopscience.iop.org
Superconducting transition edge sensor (TES) bolometers require superconducting films to
have controllable transition temperatures T c in different practical applications. The value of …

Surface micromachining for transition-edge detectors

GC Hilton, JA Beall, S Deiker, J Beyer… - IEEE transactions on …, 2003 - ieeexplore.ieee.org
We are developing arrays of high-performance detectors based on superconducting
transition-edge sensors (TES) for application in x-ray materials analysis as well as x-ray and …

Toward a cryogenic imaging array of transition edge X-ray microcalorimeters

MP Bruijn, WB Tiest, HFC Hoevers… - X-Ray optics …, 2000 - spiedigitallibrary.org
We report on the development of an imaging detector with high energy resolution for the X-
ray Evolving Universe Spectroscopy Mission (XEUS). The type of detector we are studying is …

Transition-edge sensor microcalorimeters for a diffuse soft X-ray sounding rocket mission

KM Morgan - 2015 - search.proquest.com
The extent and composition of the soft Diffuse X-ray Background (DXRB) has been the
subject of debate since its discovery in the 1960s. Initially assumed to be extragalactic, it …

Vortex dynamics in superconducting transition edge sensors

S Ezaki, K Maehata, N Iyomoto, T Asano… - Journal of Applied …, 2018 - pubs.aip.org
The temperature dependence of the electrical resistance (RT) and the current-voltage (IV)
characteristics has been measured and analyzed in a 40 nm thick Ti thin film, which is used …