Current prevalence of myopia and association of myopia with environmental factors among schoolchildren in Japan

E Yotsukura, H Torii, M Inokuchi… - JAMA …, 2019 - jamanetwork.com
Importance Given the estimates of increasing prevalence of myopia, especially in Asia, it is
important to determine the current prevalence of myopia among populations of …

Lenstar LS900 vs EchoScan US-800: Comparison between optical and ultrasound biometry with and without contact lenses and its relationship with other biometric …

V Noya-Padin, J Garcia-Queiruga… - Expert Review of …, 2023 - Taylor & Francis
Background Due to the increasing use of contact lenses (CL) and the interest in ocular and
body size relationships, this study aimed to compare measurements from two biometers …

[HTML][HTML] Case series analysis of myopic progression control with a unique extended depth of focus multifocal contact lens

J Cooper, B O'Connor, R Watanabe, R Fuerst… - Eye & Contact …, 2018 - journals.lww.com
Objectives: To determine the rate of myopia progression in children fit with a commercially
available extended depth of focus (center distance) multifocal soft contact lens with attributes …

Comparison between Ocular Biometric Parameters and Intraocular Pressure with and without Contact Lenses

V Noya-Padin, N Nores-Palmas… - Eye & Contact Lens …, 2023 - journals.lww.com
Objectives: To compare the values of central corneal thickness, anterior chamber depth
(ACD), lens thickness (LT), vitreous length (VL), axial length (AL), and corneal-compensated …

Accuracy of intraocular lens calculations based on fellow-eye biometry for phacovitrectomy for macula-off rhegmatogenous retinal detachments

AR El-Khayat, AJ Brent, SAM Peart, PR Chaudhuri - Eye, 2019 - nature.com
Objectives To determine the accuracy of using fellow-eye biometry for intraocular lens
calculations for phacovitrectomy for macula off rhegmatogenous retinal detachments …

[HTML][HTML] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug …

Y Li, A Gokul, C McGhee, M Ziaei - Plos one, 2021 - journals.plos.org
Purpose To compare the repeatability and agreement in biometric measurements using
Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug …

[HTML][HTML] Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

T Ferrer-Blasco, JJ Esteve-Taboada… - Arquivos brasileiros de …, 2019 - SciELO Brasil
Purpose: To determine the reliability of swept-source optical coherence tomography in
cases in which soft contact lenses cannot be removed when acquiring biometric …

Refractive surprise after routine cataract surgery with multifocal IOLs attributable to corneal epithelial basement membrane dystrophy

VWM Ho, N Stanojcic, NAL O'Brart… - Journal of Cataract & …, 2019 - journals.lww.com
We describe two patients in whom postsurgical refractive error occurred after routine
refractive lens exchange cataract surgery with multifocal intraocular lens insertion most likely …

[HTML][HTML] Resultados preliminares de um algoritmo para ablação de lente de contato personalizada

L Matos, LAV Carvalho - Arquivos Brasileiros de Oftalmologia, 2009 - SciELO Brasil
OBJETIVO: Desenvolver simulação computadorizada de ablação para produzir lentes de
contato personalizadas a fim de corrigir aberrações de alta ordem. MÉTODOS: Usando …

Intraocular Lens Power Calculation Without Corneal Parameters: A New Option

N Rosa, L Zeppa, M De Bernardo, A Coppola… - Eye & Contact …, 2021 - journals.lww.com
Objectives: To compare different methods in calculating the corneal radius (R) to be used in
case of intraocular lens power calculations when it is immeasurable. Methods: The right …