[HTML][HTML] Passive, semi-active, active and hybrid mass dampers: A literature review with associated applications on building-like structures

L Koutsoloukas, N Nikitas, P Aristidou - Developments in the Built …, 2022 - Elsevier
In this paper, a state-of-the-art literature review is presented emphasising on the
development of control variants for mass damper schemes on building-like structures …

A critical review on control strategies for structural vibration control

ZR Wani, M Tantray, EN Farsangi, N Nikitas… - Annual Reviews in …, 2022 - Elsevier
In recent years, the application of structural control strategies to attenuate the dynamic
response of civil engineering structures subjected to human-induced and environmental …

Recent advances in hybrid vibration-control systems

MH Stanikzai, S Elias, Y Chae - Practice Periodical on Structural …, 2022 - ascelibrary.org
A detailed literature review of the recent advances in hybrid vibration-control systems was
presented in this article. In the literature, a combination of two or more vibration-control …

Smart hybrid VIV control of a linearly sprung cylinder using an internal semi-active NES-based vibration absorber coupled with two active rotating wake-control rods

SM Hasheminejad, Y Masoumi - Ocean Engineering, 2022 - Elsevier
Extensive two dimensional CFD simulations were carried out to investigate the hybrid
active/semi-active cross-flow vortex induced vibration (VIV) suppression of a flexibly …

Experimental study on vibration control of suspended piping system by single-sided pounding tuned mass damper

J Tan, SC Michael Ho, P Zhang, J Jiang - Applied Sciences, 2019 - mdpi.com
Featured Application The presented device aims to passively suppress the vibrations of
suspended piping systems and improve structural resiliency and occupant safety. Abstract …

Sound transmission control through a hybrid smart double sandwich plate structure

SM Hasheminejad… - Journal of Sandwich …, 2021 - journals.sagepub.com
A three-dimensional analytical model is developed for control of sound transmission through
an acoustically baffled simply supported hybrid smart double sandwich panel partition of …

Robust structural control of a real high‐rise tower equipped with a hybrid mass damper

L Koutsoloukas, N Nikitas… - The Structural Design of …, 2022 - Wiley Online Library
In this paper, the robust control of a real high‐rise tower is studied, using a newly proposed,
in the structural control field, Robust Model Predictive Control scheme (RMPC). Two RMPC …

[HTML][HTML] Semi-active Vibration Control of Soft-Storey Building with Magnetorheological Damper Under Seismic Excitation

K Bhowmik, N Debnath - Journal of Vibration Engineering & Technologies, 2024 - Springer
Purpose Semi-active control is considered to be very interesting for its engineering
sophistication/effectiveness like the active control strategy, however, requiring significantly …

Experimental study on robustness of an eddy current-tuned mass damper

J Chen, G Lu, Y Li, T Wang, W Wang, G Song - Applied Sciences, 2017 - mdpi.com
In this paper, an eddy current tuned mass damper (ECTMD) is utilized to control the vibration
of a cantilever beam. The robustness of the ECTMD against frequency detuning is …

Semi‐active algorithm for energy‐based predictive structural control using tuned mass dampers

DH Zelleke, VA Matsagar - Computer‐Aided Civil and …, 2019 - Wiley Online Library
A novel semi‐active control algorithm is developed and numerically evaluated for the
suppression of undesirable structural vibrations. The mechanical energy of the vibrating …