A robust circuit and controller parameters' identification method of grid-connected voltage-source converters using vector fitting algorithm

W Zhou, RE Torres-Olguin, F Göthner… - IEEE Journal of …, 2021 - ieeexplore.ieee.org
This article presents a vector fitting (VF) algorithm-based robust circuit and controller
parameters' identification method for grid-connected voltage-source converters (VSCs). The …

Design of digital filter-based highly robust active damping for LCL-filtered grid-tied inverters

P Cai, X Wu, Y Yang, W Yao, W Liu… - 2018 IEEE 4th …, 2018 - ieeexplore.ieee.org
Damping is required in grid-connected LCL-filtered inverters. Due to additional power losses
caused by passive elements, active damping is more favorable. As an active damping …

A gray-box parameters identification method of voltage source converter using vector fitting algorithm

W Zhou, Y Wang, Z Chen - … and ECCE Asia (ICPE 2019-ECCE …, 2019 - ieeexplore.ieee.org
This paper presents a vector fitting (VF) algorithm-based gray-box structure and parameters
identification method for voltage source converter (VSC). Terminal impedance frequency …

Improved Pole Placement and Compaction of MIMO Vector Fitting Applied to System Identification

AM Smith, S D'Arco, JA Suul… - IEEE Transactions on …, 2024 - ieeexplore.ieee.org
In this work we address the modeling of multi-port subsystems with unknown inner dynamics
by utilizing vector fitting to identify state-space models for performing eigenvalue-based …

Frequency and temperature-dependent power cable modelling for stability analysis of grid-connected inverter

W Zhou, Y Wang, Z Chen - 2018 IEEE 4th Southern Power …, 2018 - ieeexplore.ieee.org
This paper presents a RLC circuit model of long transmission cable (LTC) with consideration
of frequency and temperature-dependent characteristics. Per-unit-length (pu 1.) impedance …

A gray-box impedance reshaping method of grid-connected inverter for resonance damping

W Zhou, Y Wang, P Cai, Z Chen - 2019 10th International …, 2019 - ieeexplore.ieee.org
Oscillation phenomenon of grid-connected inverter can be caused due to time-varying grid
impedance. Terminal output impedance of inverter can be reshaped by re-tuning internal …

Decoupled multi-port impedance modelling method of transmission network in inverter-fed power plant

W Zhou, Y Wang, Z Chen - 2018 International Conference on …, 2018 - ieeexplore.ieee.org
This paper presents a decoupled multi-port impedance modelling method of transmission
network for stability analysis of inverter-fed power plant. The decoupled three-port and four …

Comparison of star and string offshore dc collector grid topologies on the aspect of stability—an impedance approach

M Biskoping, T Kadam, SK Gurumurthy, F Ponci… - Energies, 2021 - mdpi.com
Offshore Direct Current (DC) collector grids are a promising technology for decreasing the
installation and operation costs of offshore wind parks. Nevertheless, the stability properties …

Impedance-based modelling method for length-scalable long transmission cable for stability analysis of grid-connected inverter

W Zhou, Y Wang, Z Chen - 2018 IEEE 4th Southern Power …, 2018 - ieeexplore.ieee.org
This paper presents an impedance-based modelling method for length-scalable long
transmission cable (LTC), which is able to assess influence of LTC on stability of grid …

Vector fitting-based reduced order modelling method for power cables

W Zhou, Y Wang, Z Chen - … Conference on AC and DC Power …, 2019 - ieeexplore.ieee.org
To study the frequency and damping characteristics of power cable, high-order RLC circuit
models are commonly required, which involves high computational burdens for modelling …