Application of micro-and nanoprobes to the analysis of small-sized 3D materials, nanosystems, and nanoobjects

AD Pogrebnjak, AG Ponomarev, AP Shpak… - Physics …, 2012 - iopscience.iop.org
The basic physics behind the interaction of ions with solid-state matter is discussed, with an
emphasis on the formation of interaction products between the ions and target atoms …

Beam optics in nuclear microprobe: A review

AG Ponomarev, AA Ponomarov - … and Methods in Physics Research Section …, 2021 - Elsevier
The beam optics in a nuclear microprobe is considered on the basis of quality criteria for
focusing systems. In this consideration, empirical criteria with dominant chromatic or intrinsic …

The Sumy scanning nuclear microprobe: Design features and first tests

VE Storizhko, AG Ponomarev, VA Rebrov… - Nuclear Instruments and …, 2007 - Elsevier
A new scanning nuclear microprobe based on a single-ended 2MV Van de Graaff
accelerator has recently been designed and constructed at the Sumy Institute of Applied …

Применение микро-и нанозондов для анализа малоразмерных 3D материалов, наносистем и нанообъектов

АД Погребняк, АГ Пономарев, АП Шпак… - Успехи физических …, 2012 - ufn.ru
Согласно прогнозам ведущих экспертов, к середине XXI в. планируется значительный
рывок в использовании наноматериалов и нанотехнологий в авиации, космосе …

Numerical optimization of magnetic nonlinear quadrupole systems in an ion microprobe with given spot size on the target

VA Brazhnik, AD Dymnikov, DN Jamieson… - Nuclear Instruments and …, 1995 - Elsevier
The beam emittance is maximized for a given beam spot size. Five magnetic quadrupole
systems (one triplet and four Russian quadruplets) are numerically investigated taking into …

Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

AG Ponomarev, KI Melnik, VI Miroshnichenko… - Nuclear Instruments and …, 2003 - Elsevier
Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution
better than 0.1 μm with a beam current of∼ 100 pA have been connected with microprobes …

Current Status of the IAP NASU accelerator-based Analytical Facility

OM Buhay, AA Drozdenko, MI Zakharets, IG Ignat'ev… - Physics Procedia, 2015 - Elsevier
Accelerator-based analytical facility (AAF) of the Institute of Applied Physics of the National
Academy of Sciences of Ukraine is described. The research facility is based on a compact …

Design of 50 MeV proton microbeam based on cyclotron accelerator

HJ Mou, GB Mao, JQ Zhang, C Zhao, JL Guo… - Nuclear Science and …, 2023 - Springer
High-energy proton microbeam facilities are powerful tools in space science, biology and
cancer therapy studies. The primary limitations of the 50 MeV proton microbeam system are …

Optimal non-linear, orthomorphic, magnetic quadrupole lens systems for ion microprobes

AD Dymnikov, DN Jamieson, GJF Legge - Nuclear Instruments and …, 1995 - Elsevier
The lens strengths, demagnifications and spherical aberrations of many different quadrupole
focusing systems for an ion microprobe are calculated and compared. The paper studies …

Optimization of magnetic quadrupole probe forming systems based on separated Russian quadruplet

VA Brazhnik, VI Miroshnichenko, AG Ponomarev… - Nuclear Instruments and …, 2001 - Elsevier
This paper describes computer simulation of the optimum lens arrangement and collimator
slit dimensions in magnetic quadrupole probe forming systems based on separated Russian …