Transient wave-based methods for anomaly detection in fluid pipes: A review

TC Che, HF Duan, PJ Lee - Mechanical Systems and Signal Processing, 2021 - Elsevier
Over the years, anomaly detection of fluid pipes has been a focus of water authorities as well
as oil and gas operators to advance the operation and management of these mechanical …

Review of model-based and data-driven approaches for leak detection and location in water distribution systems

Z Hu, B Chen, W Chen, D Tan, D Shen - Water Supply, 2021 - iwaponline.com
Leak detection and location in water distribution systems (WDSs) is of utmost importance for
reducing water loss, which is, however, a major challenge for water utility companies. To this …

Leak detection and topology identification in pipelines using fluid transients and artificial neural networks

J Bohorquez, B Alexander, AR Simpson… - Journal of Water …, 2020 - ascelibrary.org
Condition assessment of water pipelines using fluid transient waves is a noninvasive
technique that has been investigated for the past 25 years. Approaches to identify different …

Leak localization in water networks: A model-based methodology using pressure sensors applied to a real network in Barcelona [applications of control]

R Perez, G Sanz, V Puig, J Quevedo… - IEEE control systems …, 2014 - ieeexplore.ieee.org
The efficient distribution of water is a subject of major concern for water utilities and
authorities [1]. While some leaks in water distribution networks (WDNs) are unavoidable …

Leak localization in water distribution networks using Bayesian classifiers

A Soldevila, RM Fernandez-Canti, J Blesa… - Journal of Process …, 2017 - Elsevier
This paper presents a method for leak localization in water distribution networks (WDNs)
based on Bayesian classifiers. Probability density functions for pressure residuals are …

Anomaly pre-localization in distribution–transmission mains by pump trip: preliminary field tests in the Milan pipe system

S Meniconi, B Brunone, M Ferrante… - Journal of …, 2015 - iwaponline.com
In this paper, the reliability of transients due to pump trip as a powerful tool for the pre-
localization of anomalies in real pipe systems is tested. The examined pipe system is part of …

Leak localization in water distribution networks using a mixed model-based/data-driven approach

A Soldevila, J Blesa, S Tornil-Sin, E Duviella… - Control Engineering …, 2016 - Elsevier
This paper proposes a new method for leak localization in water distribution networks
(WDNs). In a first stage, residuals are obtained by comparing pressure measurements with …

Time-reversal technique for pipeline defect detection

M Waqar, M Louati, MS Ghidaoui - Water research, 2023 - Elsevier
In this paper, time-reversal (TR) technique is proposed for the detection of discrete defects
(eg, leaks and blockages) in pressurized fluid-filled pipelines using active transient waves …

Matched-field processing for leak localization in a viscoelastic pipe: An experimental study

X Wang, J Lin, A Keramat, MS Ghidaoui… - … Systems and Signal …, 2019 - Elsevier
This paper applies the matched-field processing (MFP) method to leakage localization in a
viscoelastic pipe. The viscoelasticity of pipe wall is included in the governing equations of …

A review of physical experiments for leak detection in water pipes through transient tests for addressing future research

B Brunone, F Maietta, C Capponi… - Journal of Hydraulic …, 2022 - Taylor & Francis
Since the 1990s, pressure waves propagating in pressurized pipes during a transient event
have been re-evaluated both in the laboratory and in real systems as a way to obtain …