Carbon dioxide generation rates for building occupants

A Persily, L de Jonge - Indoor air, 2017 - Wiley Online Library
Indoor carbon dioxide (CO 2) concentrations have been used for decades to characterize
building ventilation and indoor air quality. Many of these applications require rates of CO 2 …

Smart ventilation energy and indoor air quality performance in residential buildings: A review

G Guyot, MH Sherman, IS Walker - Energy and Buildings, 2018 - Elsevier
To better address energy and indoor air quality issues, ventilation needs to become smarter.
A key smart ventilation concept is to use controls to ventilate more at times it provides either …

Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self‐assessed acute health symptoms, and cognitive performance

X Zhang, P Wargocki, Z Lian, C Thyregod - Indoor air, 2017 - Wiley Online Library
The purpose of this study was to examine the effects on humans of exposure to carbon
dioxide (CO 2) and bioeffluents. In three of the five exposures, the outdoor air supply rate …

Poor ventilation worsens short‐range airborne transmission of respiratory infection

Y Li, P Cheng, W Jia - Indoor air, 2022 - Wiley Online Library
To explain the observed phenomenon that most SARS‐CoV‐2 transmission occurs indoors
whereas its outdoor transmission is rare, a simple macroscopic aerosol balance model is …

Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings

OA Seppänen, WJ Fisk, MJ Mendell - Indoor air, 1999 - Wiley Online Library
This paper reviews current literature on the associations of ventilation rates and carbon
dioxide concentrations in non‐residential and non‐industrial buildings (primarily offices) …

Challenges in developing ventilation and indoor air quality standards: The story of ASHRAE Standard 62

A Persily - Building and Environment, 2015 - Elsevier
Building ventilation has long been recognized for its role in occupant health, comfort and
productivity, with some of the first recommendations on building ventilation rates published …

Quality criteria for multi-domain studies in the indoor environment: Critical review towards research guidelines and recommendations

G Chinazzo, RK Andersen, E Azar… - Building and …, 2022 - Elsevier
The perception, physiology, behavior, and performance of building occupants are influenced
by multi-domain exposures: the simultaneous presence of multiple environmental stimuli, ie …

The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity

P Wargocki, DP Wyon, G Clausen, PO Fanger - 2000 - aivc.org
Abstract Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity
were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow …

Evaluation of olfactory dysfunction in the Connecticut chemosensory clinical research center

WS Cain, RB Goodspeed, JF Gent… - The …, 1988 - Wiley Online Library
The olfactory test administered to patients at the Connecticut Chemosensory Clinical
Research Center combines stability of outcome with sensitivity to variables known to affect …

Impact of temperature and humidity on the perception of indoor air quality

L Fang, G Clausen, PO Fanger - Indoor air, 1998 - Wiley Online Library
Sensory responses to clean air and air polluted by five building materials under different
combinations of temperature and humidity in the ranges 18‐28° C and 30‐70% RH were …